Kenwood KDC-CX85 Service Manual page 11

Cd auto changer
Hide thumbs Also See for KDC-CX85:
Table of Contents

Advertisement

A
B
(X13-9790-00)
1
IC1
: UPD78058GCB82T
IC2
: PST9137NR
Q1,2,7,8
: DTC124EK
Q3,4
: DTB123YK
Q5,6
: 2SC2412K
D1-6
: MA3056WA
D7
: DAP202K
D8-10,15 : DAN202K
D11
: MA3062-L
D12,13
: MA3056-M
D14
: DA204K
SIGNAL LINE
GND LINE
D14
2
B LINE
S1
OFF
AUX SW
ON
J1,2
1
5
9
2
6 10
13
3
7 11
4
8 12
3
R41
10K
J1
J2
1
REQH0
REQH2
2
GND
GND
3
BU+14V
BU+14V
Q5,6
4
CHCON
CHCON02
5
CH MUTE
CH MUTE2
CH-CON SW
6
AGND
AGND2
7
CH RST
CH RST2
8
Rch
Rch2
REQC0
REQC2
9
R32
D11
10
DATAC0
DATAC2
2.2K
11
DATAH0
DATAH2
12
Lch
Lch2
13
HCLK0
HCLK2
4
R10 100
D4
D8
R12 100
to H.U
J1
R15 100
1
5
9
R14 100
2
6
10
R16 100
13
R13 100
3
7
11
5
4
8
12
R9 100
D5
D6
D7
R11
100
R2 100
to CH2
R4 100
6
J2
R7 100
1
5
9
R6 100
2
6
10
R8 100
13
R5 100
3
7
11
R3 100
4
8
12
R1 100
D1
D2
D3
7
C
D
RESET SW
5.0V
4
Q8
R47
R46
10K
22K
100K
5.0V
5
22K
IC2
RESET IC
Q7
MOMENTARY
POWER
DOWN SW
0V
61
5.0V
61
REQC2
0V
62
BUDET
Q7
D13
R48
22K
18K
22K
0V
R45
1K
63
AUX SW
64
64
REQH0
R36
100
65
65
REQC1
R40
1K
0V
66
CHCON1
R28
1K
Q6
5.0V
67
67
COMMSW
R42
5.0V
68
VDD
1K
69
5V
X2
0V
70
4V
X1
1V
X1 4.19MHz
0V
71
IC
72
0V
R30
1K
5.0V
73
CHCON2
5.0V
74
R31
Q5
AVDD
1K
0V
75
AVREF0
76
R27
77
0V
100K
78
4
79
80
64
11
14
12
13
11
K4
K2
4
L
R
CH/AUX
7
15
K3
K1
CH1/CH2
L
R
61
16
18
17
20
E
F
3
2
1
40
39
38
37
D15
36
35
34
33
0V
VSS
32
31
C5
47u6.3
30
+
29
C3
28
0.01
19
27
26
IC1
25
11
u-COM
24
9
8
10
65
6
R23
23
0V
100
MSTOP
22
0V
RELAY2
22
67
21
0V
RELAY1
21
5.0V
0V
5.0V
5.0V
20
D10
Q4
Q2
22K
21
22K
D9
Q3
Q1
22K
22
22K
Q1-4
RELAY DRIVE
G
H
2SB1565
DTA114EK DTA124EK
DTA143EK DTB123YK
DTC124EK 2SA1362
2SC2412K 2SD2114K
CN1
20
BU14V
19
BU14V
18
RESET
17
Rch1
16
AGND1
2SB1188
15
Lch1
X32-
CN1
14
CH CON01
13
GND
2/2
12
GND
11
CH MUTE1
A
10
DATAH1
9
DATAC1
8
HCLK1
NJM4565MD
7
REQC1
6
REQH1
NJM5532MD
5
MGND
4
MGND
3
+5V
2
MSTOP
1
COMMSW
DAN202K
TA78L05F
CN2
AGND
4
4
Lch+
L
3
3
AUX
AGND
2
2
Rch+
R
1
1
CAUTION : For continued safety, replace safety critical components only with manufacturer's
recommended parts (refer to parts list).
Indicates safety critical components. To reduce the risk of electric shock, leakage-current or
!
resistance measurements shall be carried out (exposed parts are acceptably insulated from the
supply circuit) before the appliance is returned to the customer.
• DC voltages are as measured with a high impedance voltmeter. Values may vary slightly due to