Horizontal Airflow - Panasonic CS-E7NKEW Service Manual

Indoor / outdoor unit
Hide thumbs Also See for CS-E7NKEW:
Table of Contents

Advertisement

Cooling
Dry
Heating
1
Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the
angles as stated above. For heating mode operation, the angle of the vane depends on the indoor heat
exchanger temperature as Figure 1 below. It does not swing during fan motor stop. When the air conditioner
is stopped using remote control, the vane will shift to close position.
2
Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated above
and the positions of the vane are as Figure 2 below. When the air conditioner is stopped using remote control,
the vane will shift to close position.
12.4.2

Horizontal Airflow

Automatic horizontal airflow direction can be set using remote control; the vane swings left and right within the
angles as stated below. For heating mode operation, the angle of the vane depends on the indoor heat
exchanger temperature as Figure 1 below. It does not swing during fan motor stop.
Heating, with heat exchanger temperature
Cooling and soft dry
Manual horizontal airflow direction can be set using remote control; the angles of the vane are as stated below
and the positions of the vane are as Figure 2 above.
Pattern
Airflow Direction
Patterns at Remote
Control
Vane Angle (°)
Operation Mode
Usual (Ventilation)
Auto
Control with dew
Usual (Ventilation)
Manual
Control with dew
Usual
Auto
Control with dew
Usual
Manual
Control with dew
Manual
Usual
E18~21NK
Operation Mode
1
2
90
65
CS-E7, 9, 12, 15NK CS-XE7, 9, 12, 15NK
Vane Angle (°)
1
2
3
5 ~ 35
5 ~ 35
5
12.5
20
5
12.5
20
5 ~ 35
5 ~ 35
5
12.5
20
5
12.5
20
5
17.5
30
Vane Angle (°)
A
65 ~115
B
65 ~115
3
77.5
71
4
5
27.5
35
27.5
35
27.5
35
27.5
35
42.5
55
90
4
5
102.5
115

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents