PARAMETER LIST
Name
Parameters
STR terminal
179
function selection
RL terminal function
180
selection
RM terminal
181
function selection
RH terminal
182
function selection
RT terminal function
183
selection
AU terminal
184
function selection
JOG terminal
185
function selection
CS terminal function
186
selection
MRS terminal
187
function selection
STOP terminal
188
function selection
RES terminal
189
function selection
RUN terminal
190
function selection
SU terminal function
191
selection
IPF terminal
192
function selection
OL terminal function
193
selection
FU terminal function
194
selection
ABC1 terminal
195
function selection
ABC2 terminal
196
function selection
232
Multi-speed setting
to
(speeds 8 to 15)
239
Soft-PWM operation
240
selection
Analog input
241
display unit
switchover
Terminal 1 added
242
compensation
amount (terminal 2)
*1
Setting of "7, 107" can be made for the FR-F720-03160 (FR-F740-01800) or more.
16
Setting
Initial
Range
Value
0 to 8, 10 to 12,
14, 16, 24, 25,
61
61, 62, 64 to 67,
70 to 72, 9999
0
0 to 8, 10 to 14,
1
16, 24, 25, 62,
64 to 67, 70 to
2
72, 9999
3
0 to 8, 10 to 14,
16, 24, 25, 62 to
4
67, 70 to 72,
9999
5
6
0 to 8, 10 to 14,
16, 24, 25, 62,
24
64 to 67, 70 to
72, 9999
25
62
0 to 5, 7, 8,
0
10 to 19, 25, 26,
45 to 48, 64,
1
70 to 79, 85, 90
to 96, 98, 99,
100 to 105, 107,
2
108, 110 to 116,
125, 126,
145 to 148, 164,
3
170, 179, 185,
190 to 196, 198,
4
199, 9999
*1
0 to 5, 7, 8, 10
to 19, 25, 26,
45 to 48, 64, 70
99
to 79, 85, 90,
91, 94 to 96,
98, 99,100 to
105, 107, 108,
110 to 116,
125, 126, 145
to 148, 164,
9999
170, 179, 185,
190, 191, 194
to 196,198,
199, 9999
*1
0 to 400Hz,
9999
9999
0, 1
1
0, 1
0
0 to 100%
100%
Name
Parameters
Terminal 1 added
243
compensation
amount (terminal 4)
Cooling fan
244
operation selection
245
Rated slip
Slip compensation
246
time constant
Constant-power
range slip
247
compensation
selection
250
Stop selection
Output phase loss
251
protection selection
252
Override bias
253
Override gain
Life alarm status
255
display
Inrush current limit
256
circuit life display
Control circuit
257
capacitor life
display
Main circuit
258
capacitor life
display
Main circuit
259
capacitor life
measuring
PWM frequency
260
automatic
switchover
Power failure stop
261
selection
Subtracted
262
frequency at
deceleration start
Subtraction starting
263
frequency
Power-failure
264
deceleration time 1
Power-failure
265
deceleration time 2
Power failure
deceleration time
266
switchover
frequency
Terminal 4 input
267
selection
Monitor decimal
268
digits selection
Parameter for manufacturer setting.
269
Do not set.
Rotation direction
299
detection selection
at restarting
RS-485
331
communication
station
Setting
Initial
Range
Value
0 to 100%
75%
0, 1
1
0 to 50%,
9999
9999
0.01 to 10s
0.5s
0, 9999
9999
0 to 100s,
1000 to 1100s,
9999
8888, 9999
0, 1
1
0 to 200%
50%
0 to 200%
150%
(0 to 15)
0
(0 to 100%)
100%
(0 to 100%)
100%
(0 to 100%)
100%
0, 1
0
0, 1
1
0, 1, 2, 21, 22
0
0 to 20Hz
3Hz
0 to 120Hz,
60Hz
9999
0 to 3600/ 360s
5s
0 to 3600/ 360s,
9999
9999
0 to 400Hz
60Hz
0, 1, 2
0
0, 1, 9999
9999
0, 1, 9999
9999
0 to 31
0
(0 to 247)