7.2
W
D
IRING
IAGRAM FOR
C
ONNECTION TO AN
A
U
RISTON
NVENTED
C
YLINDER
1
3
2
T6360B
ROOM
THERMOSTAT
BROWN
BLUE
GREY
ORANGE
GREEN/YELLOW
V4043H
HEATING VALVE
BROWN
BLUE
GREY
ORANGE
GREEN/YELLOW
V4043H
HOT WATER VALVE
L
N
E
240V
MAINS INPUT (3 AMP)
Cylinder
thermostat
1
Thermal
C/P
cut-out
1 C/P
2
4
5
2
TYPICAL
JUNCTION BOX
5
2
9
10
3
8
2
9
10
3
1
2
3
• 10
1
8
6
P
Not
2
used
BOILER ELECTRICAL SUPPLY CABLE
• 1
• 2
• 3
• 4
• 5
• 6
• 7
• 8
• 9
23
Remove internal time clock plug
from the the P.C.B. then connect
room stat terminal block on the
reverse of the boiler control panel
(see section 2.10) to 9 + 10 on
the junction box.