Ariston Type C Installation Instructions Manual page 11

Type c boilers g.c.n. 47-116-14 47-116-15
Table of Contents

Advertisement

23 MFFI
Exhaust
Type
C12 (xx)
Coaxial
Systems
C32 (xx)
ø 60/100
C42 (xx)
Exhaust
Type
C12 (xy)
C32 (xy)
Twin Pipe
Systems
C42 (xy)
ø 80/80
C52 (xy)
C82 (xy)
27 MFFI
Exhaust
Type
C12 (xx)
Coaxial
Systems
C32 (xx)
ø 60/100
C42 (xx)
Exhaust
Type
C12 (xy)
C32 (xy)
Twin Pipe
Systems
C42 (xy)
ø 80/80
C52 (xy)
C82 (xy)
Restrictor
Restrictor
ø 41 mm
ø 47 mm
L min = 0.5 m
L min = 2 m
L max = 2 m
L max = 4 m
Restrictor
Restrictor
ø 41 mm
ø 47 mm
L max = 11.5 m
L min = 11.5 m
L max = 43 m
L max = 16 m
L min = 16 m
L max = 43 m
Restrictor
ø 41 mm
NO Restrictor
L min = 0.5 m
L min = 1 m
L max = 1 m
L max = 4 m
Restrictor
ø 41 mm
NO Restrictor
L max = 38 m
L min = 38 m
L max = 62 m
L max = 34 m
L min = 34 m
L max = 54 m
Maximum
Risk of Condensation Forming
Extension
Piping not insulated
Exhaust/Air
ø 41
restrictor
L = 4 m
NONE
Maximum
Risk of Condensation Forming
Extension
Piping not insulated
Exhaust/Air
ø 41
restrictor
43 m
43 m
4.3 m
43 m
43 m
4.7 m
Maximum
Risk of Condensation Forming
Extension
Piping not insulated
Exhaust/Air
ø 41
restrictor
L = 4 m
NONE
Maximum
Risk of Condensation Forming
Extension
Piping not insulated
Exhaust/Air
ø 41
restrictor
62 m
62 m
8 m
62 m
54 m
8 m
L = Sum of the total length of exhaust + air intake piping.
11
Piping insulated
ø 41
ø 47
restrictor
NONE
NONE
Piping insulated
ø 41
ø 47
restrictor
NONE
6.9 m
10 m
6.9 m
Piping insulated
NO
ø 41
restrictor
restrictor
NONE
NONE
Piping insulated
ø 41
NO
restrictor
restrictor
19 m
11 m
19 m
11 m
T
2.1
ABLE
ø 47
NONE
ø 47
NONE
NONE
NO
restrictor
NONE
NO
restrictor
31 m
31 m