Philips BP2.2U Service Manual page 16

Color television
Table of Contents

Advertisement

EN 16
5.
BP2.2U, BP2.3U
How to Exit CSM
Press any key on the RC-transmitter (with exception of the
"CHANNEL +/-", "VOLUME", "MUTE" and digit (0-9) keys).
5.3
Stepwise Start-up
The stepwise start-up method, as known from FTL/FTP sets is
not valid any more. The situation for this chassis is as follows:
when the TV is in a protection state detected via the Stand-by
Processor (and thus blinking an error) and SDM is activated via
shortcutting the pins on the SSB, the TV starts up until it
reaches the situation just before protection. So, this is a kind of
automatic stepwise start-up. In combination with the start-up
diagrams below, you can see which supplies are present at a
certain moment.
Important to know here is, that if e.g. the 3V3 detection fails
(and thus error 11 is blinking) and the TV is restarted via SDM,
the Stand-by Processor will enable the 3V3, but will not go to
protection now. The TV will stay in this situation until it is reset
(Mains/AC Power supply interrupted).
The abbreviations "SP" and "MP" in the figures stand for:
SP: protection or error detected by the Stand-by
Processor.
MP: protection or error detected by the VIPER Main
Processor.
Service Modes, Error Codes, and Fault Finding
Mains
"off"
- WakeUp requested
- Acquisition needed
Stand-by
(Off St-by)
- No data Acquisition required
and no POD present
- Tact SW pushed
- WakeUp requested
- Acquisition needed
- POD Card remove
d
- Tact SW pushed
POD
Stand-by
On
Figure 5-2 Transition diagram
Off
Mains
"on"
WakeUp
requested
Semi
Stand-by
- St-by requested
- Tact SW pushed
No data Acquisition
WakeUp
required and
requested
POD present
GoToProtection
GoToProtection
Protection
Active
GoToProtection
F_15400_095.eps
300505