Building Design Flexibility; Quality And Reliability; Features; Table Of Contents - Carrier 30GTN Product Data

Air-cooled reciprocating liquid chillers with comfort link controls 50 hz
Table of Contents

Advertisement

This Carrier exclusive provides smart
control and intelligent machine capacity
staging. Unlike many chillers, Carrier
model 30GTN,GTR,GBN,GBR chillers
do not require constant fluid flow. The
ability to operate with variable flow also
allows building owners to realize even
greater overall system energy savings in
the chilled water pumping system of up
to 85%, and not just at the chiller.
Full and part load efficiency
advantage
The 30GTN,GTR,GBN,GBR chillers
with
ComfortLink
control
outstanding efficiencies (EER [Energy
Efficiency Ratio], COP [coefficient of
performance], and IPLV [integrated part
load value]) in both full (up to 10.0
EER) and part load operation (IPLVs up
to 14.7). Increased part load efficiency is
provided
by
dual
refrigeration circuits, suction cutoff
unloading, and return fluid temperature
compensation.
The fully integrated ComfortLink
control
system
maintains
control over the compressors, unloaders,
expansion valves, and condenser fans to
optimize performance as conditions
change. The Carrier exclusive longstroke
electronic
expansion
valve
operates
at
reduced
pressures, thereby allowing the control to
operate the fans down to lower outdoor
temperatures. By utilizing valve position
information, the control maintains the
highest possible evaporator pressure and
minimizes the excessive superheat that
conventional thermal expansion valve
(TXV) systems require. Wider operating
ranges equal increased efficiencies and
lower installed costs.

Building design flexibility

Design and consulting engineers will
appreciate the broad selection of sizes
and wide operating range offered by the
30GTN,GTR,GBN,GBR chillers. With
built-in dual chiller control, imaginative
large tonnage systems can be easily
engineered and controlled with smaller,
easier to handle modules. Modular
design allows engineers to consider side
by side, offset, or angled placement to fit
the awkward spaces that the architect
sometimes
systems. Or, in the case of planned
expansion, additional cooling can be
offer
brought on-line and controlled from the
same system.
In some places facility managers
may find that the cash flow provided by
building up large air cooled multi-chiller
plants can easily offset any efficiency
losses when compared to large water
independent
cooled centrifugal type chilled water
plants.

Quality and reliability

To
assure
efficient
performance, every chiller is factory run
tested. Individual components are also
tested at many levels to assure that only
the
30GTN,GTR,GBN,GBR chillers. Long
(EXV)
life and reliability are also a function of
condensing
design. While some manufacturers like
to talk about moving parts, Carrier's
engineers
dangers to chiller systems caused by
problems in the power distribution
system.
imbalances are but a few of the
conditions that can hurt the compressor's
motor.

Table of contents

Page
Features/Benefits .............................................................................................. 1-3
Model Number Nomenclature ..............................................................................4
Physical Data .................................................................................................. 5-10
Base Unit Dimensions .................................................................................. 11-17
Application Data........................................................................................... 18-23
Selection Procedure .......................................................................................24,25
Performance Data ......................................................................................... 25-27
Electrical Data ...............................................................................................28,29
Controls .........................................................................................................30,31
Typical Piping and Wiring ............................................................................32,33
Guide Specifications......................................................................................34,35
leaves
for
mechanical
long
life
and
best
parts
make
it
recognized
the
potential
Low
voltage
and
2
Model 30G chillers were one of the first
to offer ground current sensing to
prevent compressor motor burn-out that
would contaminate the system and
potentially threaten the life of future
replacement compressors. The 06E semi-
hermetic compressors are built for
performance
themselves in commercial refrigeration
equipment worldwide.
With tens of thousands of chillers
operating in all corners of the world,
end-users count on the reliability of
Carrier
30G
International Sdn. Bhd. Malaysia plant
is an ISO 9001 registered facility as are
many of Carrier's other component and
assembly plants throughout the world.

Features

• Simple and easy to use ComfortLink
communicating controls.
• Wide operating envelope from –28
to 52 C (–20 to 125 F).
• Accurate temperature control with
return fluid compensation.
quality
• Value added features built-in; dual
chiller control, reset from return.
• Superior full and part-load efficiency.
• Precise multiple-step capacity.
into
• Low noise operation (quieter than
many screw chillers).
• Dual independent refrigerant
circuits.
• Factory run tested.
• Wide range of sizes available from
stock.
• History of proven performance and
phase
reliability.
and
have
proven
chillers.
The
Carrier

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

30gtr30gbn30gbr

Table of Contents