Rf Error Codes; Table 26: Diag. - Rf Errors - Redline Communications AN-50e User Manual

An-50e system ptp / pmp user manual
Hide thumbs Also See for AN-50e:
Table of Contents

Advertisement

5.3

RF Error Codes

The terminal monitors the status of the outdoor transceiver unit and reports any
fault conditions in the system logs.
Table 26 lists the general fault conditions are reported by the system.
Error Type
AN-50e PLL
Error
Communication
Error Over IF
Cable
Radio High
Temp. Warning
Radio Power
Supply Fault
Low DC Voltage
At Radio Input
See Table 27: Diag. - RF Status Error Codes for a list of the thirty-two possible
error codes.
70-00033-01-03

Table 26: Diag. - RF Errors

Description
The PLL (Phase Locked Loop) section within the terminal
experienced an error. The System Fault LED may light. Try
resetting the terminal.
Communication between the terminal and the transceiver failed.
Check the IF cable and connectors.
The transceiver internal temperature rose above 185F / 85C. The
transceiver will shut down for 30 seconds to allow cooling time.
Indicates a fault in the transceiver power supply. This error could
be due to a problem with the internal power supply, or with the
power source from the terminal. If the Low DC Voltage At Radio
error is also indicated, (see below) check the IF cable and
connectors. If the Low DC Voltage At Radio error is not indicated,
the transceiver requires servicing.
The DC voltage at the transceiver (carried by the IF cable from the
terminal) is lower than the required 24 VDC. Check the IF cable
and connectors. The minimum required voltage for operation is 12
VDC.
Proprietary Redline Communications © 2005
Page 73 of 100
AN-50e
user manual
September 2005

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents