Daikin WMC Installation, Operation And Maintenance Manual page 53

Magnetic bearing centrifugal chillers c vintage 125 to 400 tons (440 to 1400 kw) hfc-134a refrigerant 50/60 hz
Table of Contents

Advertisement

Table 19 continued: Menu Matrix
NOTE: Screens listed in this table that have a gray background require a technician level password to manipulate.
VIEW
ALARM
CONDENSER
LOG
VIEW CONDENSER
Alarm Log: 01
Disch SH = 000.0°F
description
Approach = 00.0 F
HH:MM:SS
Subcooling= 00.0 F
MM/DD/YY
Alarm Log: 02
description
HH:MM:SS
MM/DD/YY
Alarm Log: 03
description
HH:MM:SS
MM/DD/YY
^
I
I
v
^
I
I
v
^
I
I
v
Alarm Log: 25
description
HH:MM:SS
MM/DD/YY
www.DaikinApplied.com
SET UNIT
SET COMPRESSOR SETPOINTS
SETPOINTS
SET UNIT SPs (1)
SET COMP SPs (1)
Unit Enable = Off
Demand Limit=Off
Unit Mode = Cool
Minimum Amps=010%
Source = Switches
MaximumAmps=100%
SET UNIT SPs (2)
SET COMP SPs (2)
Available Modes
StageMode =Normal
= Cool
StageSequence# = 01
Select w/Unit Off
Max Compr On = 02
SET UNIT SPs (3)
SET COMP SPs (3)
Cool LWT = 44.0°F
StageDeltaT = 1.0°F
Ice LWT = 25.0°F
Stop-Start = 03 min
Heat LWT = 135.0°F
Start-Start = 05 min
SET UNIT SPs (4)
SET COMP SPs (4)
Leaving Water Temp
UL Surg Ofs=200RPM
StartDelta= 03.0°F
Name Plate RLA 140
StopDelta = 3.0°F
SET UNIT SPs (5)
SET COMP SPs (5)
Rest Type = NONE
Lead Staging = 030%
MaxResetDT =00.0°F
Nom Capacity=0100T
StrtResetDT = 10.0°F
HG-Bypass=30% RLA
SET UNIT SPs (6)
SET COMP SPs (6)
Soft Load = OFF
IntrLokTmr=010sec
InitialSLAmps= 020%
UnloadTimer=120sec
SoftLoadRamp=05min
Max Str LWT=10.0°F
SET UNIT SPs (7)
SET COMP SPs (7)
Max/Min LWT Rates
Vane Control
Max = 1.0°F/min
Lead Start = 012%
Min = 0.4°F/min
Lag Start = 040%
SET UNIT SPs (8)
SET COMP SPs (8)
EvapRecTmr = 0.5min
Start Speed
EvapPump = #1 ONLY
Lead Str Spd = 015%
CondPump = #1 ONLY
Lag Str Spd = 003%
SET UNIT SPs (9)
SET COMP SPs (9)
Templifier Src Water
Protocol=M-Bus MSTR
No Start = 070°F
Id ent Number= 001
Delta Reset = 055°F
Baud Rate = 19200
SET UNIT SPs (10)
SET COMP SPs (10)
VFD = Yes
Refrg Sat Pressure
Harmonic Filter
Evp Offset =+00.0 psi
Engages > 06 RLA%
Cnd Offset =+00.0psi
SET UNIT SPs (11)
SET COMP SPs (11)
Max Wtr Flow Rates
ELWT Offset = +0.0 °F
Evap WF=02400GPM
Orbit Limit = A
CondWF=03000GPM
SET UNIT SPs (12)
Day Lt Saving Time
Day/Mon/Yr
24 hr time day of wk
SET UNIT SPs (13)
Refrigerant=R134a
Display=°F/psi(IP)
Lang = English
SET UNIT SPs (14)
Protocol = MODBUS
Id #= 001 Units =IP
Baud Rate = 19200
SET UNIT SPs (15)Exv
EXV Gain=078 Md078
Offset=0700 Md0700
Prs Ctrl DOut10.0°F
SET ALARM
LIMITS
SET COMP#2 SPs (1)
SET ALARM LMTs (1)
Demand Limit=Off
LowEvPrHold=27psi
Minimum Amps=010%
LowEvPrUnld=26psi
Maximum Amps=100%
LowEvPrStop=25psi
SET COMP#2 SPs (2)
SET ALARM LMTs (2)
StageMode =Normal
HighCondPr =140psi
StageSequence# = 01
HiDschT-Load=170°F
Max Compr On = 01
HiDschT-Stop=190°F"
SET COMP#2 SPs (3)
SET ALARM LMTs (3)
StageDeltaT = 1.0°F
WMC Compressor
Stop-Start = 03 min
Oilless Design
Start-Start = 05 min
(blank mask page)
SET COMP#2 SPs (4)
SET ALARM LMTs (4)
Surge Slp Str=20°F
Name Plate RLA 140
Surge Tmp Run=20°F
MtrCurThrshld=05%
SET COMP#2 SPs (5)
SET ALARM LMTs (5)
Evap Freeze= 34.0°F
Nom Capacity=0100T
Cond Freeze= 34.0°F
HG-Bypass =30%
SET COMP#2 SPs (6)
Same as Comp #1
SET COMP#2 SPs (7)
WMC Automatic
Vane Control
(blank mask page)
SET COMP#2 SPs (8)
WMC Automatic
VFD Control
(blank mask page)
SET COMP#2 SPs (9)
Starter Set Up
Same as Comp #1
SET COMP#2 SPs(10)
Refrg Sat Pressure
Evp Offset =+00.0 psi
Cnd Offset =+00.0psi
SET COMP#2 SPs (11)
Uses Comp#1 Sensor
Orbit Limit = C
51
IOM 1210-1 • MAGNITUDE
o
peraTIon
SET TOWER
SET
SETPOINTS
PASSWORD
SET TOWER SPs (1)
SET PASSWORD
TowerControl=(type?)
Enter
Tower Stages=1
Password:00000
StageUP/Dn=080/020%
No Access Given
SET TOWER SPs (2)
SET PASSWORD (2)
Stage ON
Tech Password
#1 #2 #3 #4
00000 00000
xxx xxx xxx xxx
No Access Given
SET TOWER SPs(3)Fans
VFD Min Spd = 20.0%
StageDiff= (type? Psi/F)
Stg Up=02 Dn=05 min
SET TOWER SPs (4)
Valve/VFD Control=
None
Valve Type=NC
SET TOWER SPs (5)
Valve Sp= 065°F
Reset = 20.0psi
Sensor = ECWT-B3
SET TOWER SPs (6)
ValveStartPosition
Min=010% @ 060°F
Max=100% @ 090°F"
SET TOWER SPs (7)
Valve Control Range
Min= 010% Max= 100%
Tower Loop = 1.7min
SET TOWER (8) ByP xxx%
FB +075.4 Intg Derv
Trg+075.0 006s 01g
Gain 20 D-Band01.0
SET TOWER (9) VFD xxx%
FB +075.4 Intg Derv
Trg+075.0 600s 001s
K08.0 Db0.0 Tc0500mS
Db Tower R06.5 F0653
CAF*+013 +012 UT250
Spd 120 000% S0200
RLA-05 CsP+002 m1000
MODEL WMC CHILLERS
®