Alignment And Adjustments - Samsung MW5694W Service Manual

Table of Contents

Advertisement

5. Alignment and Adjustments

1. High voltage is present at the high voltage terminals during any cook cycle.
2. It is neither necessary nor advisable to attempt measurement of the high voltage.
3. Before touching any oven components or wiring, always unplug the oven from its power source and discharge the high voltage
capacitor.
5-1 High Voltage Transformer
1. Remove connectors from the transformer terminals
and check continuity.
2. Normal resistance readings are as follows:
Secondary
Filament
Primary
(Room temperature = 20ûC)
5-2 Low Voltage Transformer
1. The low voltage transformer is located on the
control circuit board.
2. Remove the low voltage transformer from the
PCB Ass'y and check continuity.
3. Normal resistor reading is shown in the table.
5-3 Magnetron
1. Continuity checks can indicate only an open
filament or a shorted magnetron. To diagnose an
open filament or shorted magnetron :
2. Isolate the magnetron from the circuit by
disconnecting its leads.
3. A continuity check across the magnetron filament
terminals should indicate one ohm or less.
4. A continuity check between each filament terminal
and magnetron case should read open.
Samsung Electronics
PRECAUTION!
81W ± 10%
Shows Continuity
0.34W ± 10%
Primary
Terminals
Terminals
1~2(Input)
4~5(Output17V)
7~8(Output2.7V)
Magnetron Antenna
Cooling Fins
Filament Terminals
Secondary
Terminal
Resistance
SLV-5574U(DN)
SLV-5574U(CE)
264.3W
249.1W
11.22W
9.245W
2.213W
1.735W
Gasket Plate
5-1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mw5695g

Table of Contents