SA-AK23 0GCP
3. Press
4. Press "CD DIRECT PLAY (5)" and
5. Press
6. Press
7. Press "n/STOP" to indicate Error Code.
· If several problem exist, error code will change each time when "n/STOP" is pressed. (e.g. F15 → F26 → F16 ....etc).

12.5. To clear all Error code

1. Press
and hold button for 5 seconds.
2. FL indicator shows "CLEAR" for 1 second and change to "T".

12.6. To exit from Self-Diagnostic function

1. Press

12.7. Power Amplifier Failure (F61)

1. When power amplifier fail, F61 will indicate automatically .

12.8. Description of Error Code

12.8.1. Abnormality detection for Deck Mechanism block
No.
Abnormal Items
1
MODE SW abnormal
2
REC INH SW abnormal
3
HALF SW abnormal
4
Reel pulse abnormal
12.8.2. Abnormality detection for CD/Changer block
No.
Abnormal Items
1
REST SW abnormal
2
Transmission error between CD servo
LSI and micon
3
CLAMP SW abnormal
4
BOTTOM SW abnormal
5
POSITION SW abnormal
6
SW1 abnormal
7
SW2 abnormal
8
OPEN SW abnormal
9
CLOSE SW abnormal
10
DISC SENSOR
to close the tray.
and remove the CD.
to close the tray.
button on main unit or remote control.
Error Display Method of Detection
Error Display Method of Detection
wait until the tray is open.
H01
Normal operation during mecha transition, MODE SW abnormal is
memorized. The content of abnormality can be confirmed in the
abnormal detection mode explained in the later section.
H02
The content of abnormality can be confirmed in the abnormal detection
mode explained in the later section.
H03
The content of abnormality can be confirmed in the abnormal detection
mode explained in the later section.
F01
The content of abnormality can be confirmed in the abnormal detection
mode explained in the later section.
F15
Under normal operation (Self-Diagnostic Mode inclusive), this error
occurs when the REST SW ON is not detected within the specified time
and shall be memorized.
F26
Under normal operation (Self-Diagnostic Mode inclusive), this error occurs
when the selection is set to CD and SENSE='H' is detected and
SENSE='L' is not detected within a fail safe time (20ms) after system
command transmission was sent.
F16
Refer to section 12.8.4 (Mechanism Error Code Table) [M-0A] error is
detected.
F17
Refer to section 12.8.4 (Mechanism Error Code Table) [M-09] error is
detected.
F27
Refer to section 12.8.4 (Mechanism Error Code Table) [M-05 ~ M-08] error
is detected.
F28
Refer to section 12.8.4 (Mechanism Error Code Table) [M-02 ~ M-08] error
is detected.
F29
Refer to section 12.8.4 (Mechanism Error Code Table) [M-02 ~ M-08] error
is detected.
H15
Refer to section 12.8.4 (Mechanism Error Code Table) [M-01] error is
detected.
H16
Refer to section 12.8.4 (Mechanism Error Code Table) [M-01] error is
detected.
F30
Refer to section 12.8.4 (Mechanism Error Code Table) [M-01] error is
detected.