5.18. 34Error

Error occurrence conditions and check items.
Error
If the water adjustment valve does not work properly due to a defective feedback
sensor, water adjustment valve or PCB board, the system displays 34E (cleared
automatically/manually), and switches into the Safety-Shutdown mode.
Water adjustment valve close error – The system commands opening of the water
34E
Water
adjustment valve, but the valve remains closed. [Check the feedback sensor.]
Adjutment
(Cleared manually)
valve error
If the Water adjustment valve sensor open/short-circuit is detected, the system
displays an error message. If flow is sensed, the system clears the error
automatically, provides the hot water. If open/short-circuit is detected after hot
water is used, the system displays the error message.
If the 34 error occurs, connect the good Water adjustment valve to the PCB.
valve must be kept open when the water heater does not work.
If the PCB is defective, the motor keeps operating and the valve repeats open/close.
Check items
1. Defective water adjustment valve.
2. Defective PCB.
Water Adjust Valve Feed Back
output voltage normal?
©Navien America Inc. 2010
Description
Replace Water Adjust Valve
No
Or Replace PCB
Check the voltage between black and white wire of
CN 22: 0.5 - 3.0V