TYPICAL VENT INSTALLATIONS

NOTE:
When terminating vertically above 15', the
restrictor plate must be in the fully closed
position. Refer to Restricting Vertical Vents.
FIGURES 3 a-c

SPECIAL VENT INSTALLATIONS

PERISCOPE TERMINATION

Use the GD201 periscope kit to locate the air termination
above grade. The periscope must be installed so that when
final grading is completed, the bottom air slot is located a
minimum of 12 inches above grade. The maximum allow-
able vent length depends on the fireplace, as illustrated.