17-12 REAR SUSPENSION

DISPOSAL

High pressure nitrogen gas is sealed in the rear shock absorber
unit. Be sure to release gas before disposing the rear shock
absorber unit.
• Remove the valve cap.
• Press the valve with a screwdriver.
Releasing high pressure gas from the rear shock
absorber unit can be hazardous.
Place a rag over the valve and push the valve with a
screwdriver to release nitrogen gas. Do not use your
finger to push the valve, and direct the valve away
from your face and body.
WARNING