Sony Trinitron KV-34FS12T Service Manual page 5

Trinitron color tv
Table of Contents

Advertisement

更多难得资料请到江南家电维修论坛免费下载!
http://bbs.520101.com
Display of Standby/Timer LED Flash Count
2 times
4 times
5 times
LED ON 0.3 sec.
LED OFF 0.3 sec.
Diagnostic Item
+B overcurrent
I-Prot
IK
*One flash count is not used for self-diagnostic.
Stopping the Standby/Timer LED Flash
Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY/TIMER LAMP from flashing.
Self-Diagnostic Screen Display
For errors with symptoms such as "power sometimes shuts off" or "screen sometimes goes out" that cannot be confirmed, it is possible
to bring up past occurrences of failure on the screen for confirmation.
To Bring Up Screen Test
In standby mode, press buttons on the Remote Commander sequentially, in rapid succession, as shown below:
Display
Channel 5
Self-Diagnostic Screen Display
SELF DIAGNOSTIC
2: 000
3: N/A
4: 000
5: 001
101: N/A
LED OFF
3 sec.
Flash Count*
2 times
4 times
5 times
Sound volume
Power ON
Note that this differs from entering the service mode (sound volume
Numeral “0” means that no fault was detected.
Numeral “1” means a fault was detected one time only.
— 5 —