Clearance Between Presser Foot And Needle Plate - Pfaff 3827-2 Instruction Manual

3827-2/24 pfaff
Table of Contents

Advertisement

Adjustment
14

Clearance between presser foot and needle plate

.10
14 - 10
Requirement
With the presser bar lifter 1 raised there must be a distance of 5 mm between the presser
foot and the needle plate.
2
3
12
11
1
10
7
8
6
Fig.14 - 09
Screw on the gauge foot 13.
Allow the gauge foot to rest on the needle plate using the presser bar lifter 1.
Reduce the pressure on the presser bar by loosening the adjusting screw 2 (milled
nut 3).
Loosen screw 4 and press pin 5 out.
Swing the connecting joint 6 out of the fork of lever 7.
Bring the vibrating presser to its highest point by turning the handwheel and raise the
gauge foot.
7
6
13
10
9
7
4
5