values and adjust the intensity of each color group.
Manual Settings:
Manual static settings are achieved when dipswitches 8, 9, and 10 are in the
"ON" position.
RED:
Dipswitch 1 & 2 off, the red value is 0
Dipswitch 1 is on and dipswitch 2 is off, the red value is 25% (60)
Dipswitch 1 is off and dipswitch 2 is on, the red value is 50% (125)
Dipswitch 1 is on and dipswitch 2 is on, the red value is 100% (255)
GREEN:
Dipswitch 3 & 4 off, the green value is 0
Dipswitch 3 is on and dipswitch 4 is off, the green value is 25% (60)
Dipswitch 3 is off and dipswitch 4 is on, the green value is 50% (125)
Dipswitch 3 is on and dipswitch 4 is on, the green value is 100% (255)
BLUE:
Dipswitch 5 & 6 is off, the blue value is 0
Dipswitch 5 is on and dipswitch 6 is off, the blue value is 25% (60)
Dipswitch 5 is off and dipswitch 6 is on, the blue value is 50% (125)
Dipswitch 5 is on and dipswitch 6 is on, the blue value is 100% (255)
Master/Slave Mode: This mode allows up to 16 units to be linked together to run in a
sequence. In this mode the first fixture in a daisy-chain will function as the controlling unit
and all other units ("Slaves") will receive their control signal from the first unit ("Master").