COUNTER LOCATION

Select a location in a well ventilated area, close to a grounded electrical outlet. If
possible do not place the unit close to hot and/or steaming machines.
The minimum airflow clearance is: 4" (10.16 cm) in back and 12" (30.48 cm) on
top and open to the front.
IMPORTANT:
Condenser air is drawn in from the bottom of the rear panel
and discharged out the top of the rear panel. Failure to
maintain clearance space will reduce capacity of the unit
and cause premature compressor failure.
Typically the dispenser is placed using the legs to get more cup clearance. If the
dispenser is placed directly on the counter and the drip tray is freely placed on
the counter top, cup clearance is reduced. A food grade silicone sealant applied
around the base. However, supplied with the dispenser is a counter top sealing
gasket. This eliminates the need for sealant and is much easier to use.
AIR FLOW CLEARANCE
- 9 -
Quest Elite 2000 Installation Manual
Figure 4. Minimum Clearances
Publication Number: 620048922INS
AIR FLOW CLEARANCE