APPLICATIONS

This appliance is intended to be used in household and similar applications such
as the following:
Staff kitchen areas in shops, offices and other working environments.
Farm houses and by clients in hotels, motels and other residential type envi-
ronments
Bed and breakfast type environments
Catering and similar non-retail applications
This dispenser must be connected to a COLD WATER system with operating
pressure between 20 and 100 psi (138 and 690 kPa). This water source must be
capable of producing a minimum flow rate of 3 fluid ounces (88.7 milliliters) per
second. A shut off valve should be installed in the line before the dispenser.
Install a regulator in the line when pressure is greater than 100 psi (690 kPa) to
reduce it to 50 psi (345 kPa). The regulator is also necessary if the water source
has pressure fluxuations. The main water inlet is a 3/8" (9.52 mm) MFL
connection (Figure 3).
!
WARNING:
This equipment must be installed to comply with the International Plumbing
Code of the International Code Council and the Food Code Manual of the Food
and Drug Administration (FDA). For models installed outside the U.S.A., you
must comply with the applicable Plumbing/Sanitation Code for your area.
Failure to comply could result in serious injury, death or damage to the
equipment.
- 7 -
Quest Elite 2000 Installation Manual
Water
Connection
Figure 3. Plumbing Connection
Publication Number: 620048922INS