Samsung RJ040F2HX Series Installation Manual page 7

Hide thumbs Also See for RJ040F2HX Series:
Table of Contents

Advertisement

RJ052/060F3HX ** /AJ052/068FCJ3 **
Indoor unit
Outdoor unit
RJ052F3HX **
** 020/023/026/
RJ060F3HX **
030/035/052
AJ052FCJ3 **
07/09/12/18 **
AJ068FCJ3 **
RJ052F3HX ** /AJ052FCJ3 ** Outdoor unit cannot be connected to the following indoor unit combination.
- MH052FMEA/MH052FUEA/**24**/AJN052NDEHA
100 mm
or more
CAUTION
3 m as minimum pipe length: It will reduce noise and
vibration.
600 mm
minimum
300 mm
minimum
600 mm
minimum
The appearance of the unit may be different from the diagram depending on the model.
Piping length and the height
Dimension
Composition
The appearance of the unit may be different from the diagram depending on the model.
Power supply Ø, V, Hz
1,220-240,50/60
200 mm or more
160 mm or more
A
300 mm
minimum
1 Room max
3 Room total max
length
length
RJ052F3HXEA: 50m
RJ060F3HXEA:45m
20m
RJ060F3HXEB:50m
AJ052FCJ3EH:50m
AJ068FCJ3EH:50m
A,B,C
A+B+C
Make at least one round:
It will reduce noise and vibration
Piping outside diameter
Outside diameter
Unit
Liquid
** 020/023/026/
030/035/07/09/12 **
1/4"
** 052/18 **
B
Main power switch
Max height between
indoor unit & outdoor unit
15m
(H)
Gas
3/8"
1/2"
(h) (H)
C
Max height between
indoor units
7.5m
(h)
7