Gas Pressure Setting Procedure
Code
A1
0-2000 ft
Altitude
0-610 m
EX17
Manifold test
0.40 in
pressure -
(10 mm)
W.C. Low
Manifold test
1.6 in
pressure -
(40 mm)
W.C. High
ES22
Manifold test
0.40 in
pressure -
(10 mm)
W.C. Low
Manifold test
2.6 in
pressure -
(65 mm)
W.C. High
94
Natural Gas
A2
A3
2001-5200 ft
5201-7700 ft
611-1585 m
1586-2347 m
0.44 in
0.48 in
(11 mm)
(12 mm)
1.4 in
1.2 in
(35 mm)
(32 mm)
0.44 in
0.48 in
(11 mm)
(12 mm)
2.2 in
2.0 in
(57 mm)
(52 mm)
Rinnai Direct Vent Service Manual
A4
L1
7701-10200 ft
0-2000 ft
2348-3109 m
0-610 m
0.52 in
0.72 in
(13 mm)
(18 mm)
1.1 in
2.9 in
(29 mm)
(72 mm)
0.52 in
0.72 in
(13 mm)
(18 mm)
1.8 in
4.3 in
(47 mm)
(110 mm)
RHFE-433RWTA
RHFE-558RWTA
Propane Gas
L2
L3
2001-5200 ft
5201-7700 ft
611-1585 m
1586-2347 m
0.76 in
0.88 in
(19 mm)
(22 mm)
2.5 in
2.2 in
(63 mm)
(57 mm)
0.76 in
0.88 in
(19 mm)
(22 mm)
3.8 in
3.4 in
(97 mm)
(87 mm)
L4
7701-10200 ft
2348-3109 m
0.96 in
(24 mm)
2.0 in
(52 mm)
0.96 in
(24 mm)
3.1 in
(80 mm)