INSTALLER/CONFIGURATION MENU
To enter the menu: Press the Menu touch key. Press and hold for 5 seconds the Installer Config touch key. This displays
menu item #1 in Table 25 below. Press
or
to change a menu item.
Menu
Non-
Reference
Program- Program- Press
Number
mable
mable
1
1
1
2
2
2
3
3
3
4
NA
4
5
5
4
6
6
NA
7
7
5
8
8
6
9
7
9
10
10
8
11
11
9
12
10
12
13
11
13
14
14
12
15
15
13
16
16
14
17
15
17
18
18
16
19
19
17
20
20
18
21
21
19
22
22
20
23
23
21
24
24
22
25
23
25
26
24
26
27
27
25
28
26
28
98
to advance to the next menu item or
TABLE 25: CONFIGURATION MENU
Displayed
Press
(Factory
to select from
Button
Default)
listed options
MS 2
HP 1, HP 2, SS 1
(GAS)
Days, (7) P
5-1-1 or 0
PS (4)
Morning, Day,
Day, Night
E
e v
n
n i
, g
N
g i
t h
Cool-Off-
Cool-Off-Heat,
Heat-Auto
Off-Heat, Cool-Off
Cool-Off-Heat-
Cool-Off-Heat-Emer,
Emer-Auto
Off-Heat-Emer, Cool-Off
E (On)
Cr, Heat (FA)
Cr, Cool (FA)
Cr/AU, Emer (FA)
CL (OFF)
dL (On)
dL (LO)
0
4, LO to 4, HI
F
b (On)
dS (On)
AS, Heat (OFF)
AS, Cool (OFF)
CS, (OFF)
1-2-3-4-5-6
Cool Savings
HL, Heat (99)
LL, Cool (45)
L (total), P (partial),
OFF ,
Keypad Lockout
Temperature Limit
(limited temperature range)
000
001-999
FS, Heat (On)
FS, Cool (On)
Remote (OFF)
In, Remote
Outdoor Remote
LS (On)
dF (5)
Cd (15)
AO (80)
35 to 80
Change Filter
(OFF)
200 Hours
25-1975 (in increments Change filter, duration hours.
of 25 hours)
to return to a previous menu item. Press
or
Comments
Selects Multi-Stage (MS 2, No Heat Pump), Heat Pump 1
(HP 1, 1 compressor), Heat Pump 2 (HP 2, 2 compressor
or 2 speed compressor), or Single Stage.
ELE
GAS setting: furnace controls blower.
ELE setting: thermostat controls blower.
Programs per week. (0 = non-programmable)
2
Program periods per day.
4 = Morning, Day, Evening, Night
2
=
D
a
, y
N
g i
t h
System switch configuration in non heat pump mode.
System switch configuration, heat pump mode.
OFF
Selects Energy Management Recovery, E (with programming option on)
SL
Selects Adjustable Anticipation, cycle rate, Heat
SL
Selects Adjustable Anticipation, cycle rate, Cool
SL
Selects Adjustable Anticipation, cycle rate auxiliary, (This item is
only to appear if HP 1 or HP 2 is selected above).
On
Selects Compressor Lockout.
OFF
Selects Continuous Display backlight & intensity.
HI
Selects Backlight Intensity.
Selects Adjustable Ambient Temperature Display [range -4 (LO) to
+4 (HI)].
C
Selects F/ C Displa y (temperature units in Fahrenheit or Celsius).
OFF
Selects audible Beeper On/Off.
OFF
Selects Daylight Saving Time calculation.
On
Selects Automatic Schedule for comfort temperature Programming,
heat mode.
On
Selects Automatic Schedule for comfort temperature Programming,
cool mode.
Selects Cool Saving Feature & amount.
62-98
TEMPERATURE LIMIT, HEAT (max. heat set point).
46-82
TEMPERATURE LIMIT, COOL (min. cool set point).
Selects Keypad Lockout.
Selects Keypad Lockout Combination (active only if keypad Lockout
is selected).
OFF
Fast second stage of heat (not available if SS1 is selected above).
OFF
Fast second stage of cool (not available if SS1 or HP1 is selected
above).
On
Remote temperature sensor, enable/disable.
Remote temperature sensor (Indoor/Outdoor).
OFF
Local temp. Sensor enable/disable (only when Indoor Remote is
selected On).
5-50
Selects Dual Fuel Feature & setpoint (in Fahrenheit) (applicable only
when HP1 or HP2 is selected).
Selects Compressor delay in seconds (only when dF is selected >5).
0-99
Selects Auxiliary Off setpoint (applicable only when HP1 or HP2
is selected).
On
Selects Change filter feature