Start-Up Procedures - Rheem RGFG Installation Instructions Manual

Upflow high efficiency modulating condensing gas furnaces
Table of Contents

Advertisement

START-UP PROCEDURES

TO START THE FURNACE
LIGHTING INSTRUCTIONS
This appliance is equipped with a hot
surface ignition device. This device lights
the main burners each time the room
thermostat calls for heat. See the lighting
instructions on the furnace.
During initial start-up, it is not unusual for
odor or smoke to come out of any room
registers. To ensure proper ventilation, it
is recommended to open windows and
doors, before initial firing.
The furnace has a negative pressure
switch that is a safety during a call for
heat. The induced draft blower must pull
a negative pressure on the heat
exchanger to close the negative pressure
switch. The induced draft blower must
maintain at least the negative pressure
switch set point for the furnace to oper-
ate. If the induced draft blower fails to
close or maintain the closing of the nega-
tive pressure switch, a "no heat call"
would result.
1. Remove the burner compartment
control access door.
2. IMPORTANT: Be sure that the man-
ual gas control has been in the
"OFF" position for at least five min-
utes. Do not attempt to manually
light the main burners.
3. Set the room thermostat to its lowest
setting and turn off the furnace elec-
trical power.
4. Turn the gas control knob to the
"ON" position.
5. Replace the burner compartment
control access door.
66
WARNING
FAILURE TO REPLACE THE
BURNER DOOR CAN CAUSE
PRODUCTS OF COMBUSTION TO
BE RELEASED INTO THE CONDI-
TIONED AREA RESULTING IN
PERSONAL INJURY OR DEATH.
6. Turn on the manual gas stop.
7. Turn on the furnace electrical power.
8. Turn thermostat to "Heat" mode and
set the room thermostat at least
10°F above room temperature to
light the main burners.
9. After the burners are lit, set the
room thermostat to a desired tem-
perature.
FURNACE TEST MODE
See the section of this manual titled
"DIPSWITCH" under "S4" for details
about test mode.
TO SHUT DOWN
THE FURNACE
1. Set the room thermostat to its
lowest setting and turn to "OFF"
position.
2. Turn off the manual gas stop and
turn off the electrical power to the
furnace.
3. Remove the burner compartment
control access door.
4. Shut off the gas to the main
burners by turning the gas con-
trol knob to the "OFF" position.
5. Replace the burner compartment
control access door.
WARNING
SHOULD OVERHEATING
OCCUR OR THE GAS SUPPLY
FAIL TO SHUT OFF, CLOSE
THE MANUAL GAS VALVE
FOR THE APPLIANCE
BEFORE SHUTTING OFF THE
ELECTRICAL SUPPLY. FAIL-
URE TO DO SO CAN CAUSE
AN EXPLOSION OR FIRE
RESULTING IN PROPERTY
DAMAGE, PERSONAL INJURY
OR DEATH.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents