Advertisement

QAS 14 - 20 Pd
1380
VDO 2.2
1381
1382
1383
1384
1385
1386
1390
Fuel Level 1
1391
1392
1393
1394
1395
1396
USW
1400
Fuel Pump Logic
1401
1402
1403
1404
1405
1410
Fuel High
1411
1412
1413
1414
1420
Overspeed
1421
1422
1423
1424
1425
1426
1430
Overspeed
1431
1440
Engine Failure
1441
1442
1443
1444
1445
1450
Emergency Stop
1451
1452
1453
1454
1455
1460
Coolant Temperature 1
1461
1462
1463
1464
1465
1466
USW
1470
Coolant Temperature 2
1471
1472
1473
1474
1475
1476
USW
Control setup: overview parameters
2050
f/U Limits
2051
2052
Power setup: overview parameters
3070
Test
3071
3072
3073
22
SERVICE LEVEL
Setpoint
N/A
Delay
5.0s
Output Relay A
R0
Output Relay B
R0
Enable
OFF
Fail Class
Warning
CUSTOMER LEVEL
Setpoint 1
5.0%
Delay
20.0s
Output Relay A
R0
Output Relay B
R0
Enable
OFF
Fail Class
Warning
Sensor Type
N/A
CUSTOMER LEVEL
Setpoint 2
20.0%
Setpoint 3
80.0%
Pump Relay
R3
OFF
Enable
Fill Check Delay
60.0s
CUSTOMER LEVEL
Setpoint 4
98.0%
Delay
5.0s
Output Relay A
R0
Output Relay B
R0
MASTER LEVEL
Setpoint
1650rpm
Delay
3.0s
Output Relay A
R0
Output Relay B
R0
Enable
ON
Fail Class
Shutdown
MASTER LEVEL
Overspeed S2
1650rpm
SERVICE LEVEL
1.0s
Delay
Output Relay A
R0
Output Relay B
R0
Enable
ON
Fail Class
Shutdown
MASTER LEVEL
Delay
0.0s
Output Relay A
R0
Output Relay B
R0
Enable
ON
Fail Class
Shutdown
SERVICE LEVEL
Setpoint
N/A
Delay
5.0s
Output Relay A
R0
Output Relay B
R0
Enable
OFF
Fail Class
Warning
Alarm Type
High
SERVICE LEVEL
Setpoint
N/A
Delay
5.0s
Output Relay A
R0
Output Relay B
R0
Enable
OFF
Fail Class
Warning
Alarm Type
High
SERVICE LEVEL
Df max.
4.0Hz
DU max.
5%
CUSTOMER LEVEL
Setpoint
50%
Delay
300.0s
Test Breaker
OFF
1480
Oil Pressure
(40 ... 150)
1481
Setpoint
1482
Delay
(0.0 ... 100.0)
(R0 ... R3)
1483
Output Relay A
(R0 ... R3)
1484
Output Relay B
(OFF / RUN / ON)
1485
Enable
1486
Fail Class
(Warning / Trip / Trip+Stop / Shutdown)
USW
Alarm Type
1490
Fuel Level 2
(0 ... 100)
(0.0 ... 100.0)
1491
Setpoint
(R0 ... R3)
1492
Delay
1493
Output Relay A
(R0 ... R3)
1494
Output Relay B
(OFF / RUN / ON)
1495
Enable
(Warning / Trip / Trip+Stop / Shutdown)
(0 / 1 / 2)
1496
Fail Class
1700
Low Oil Pressure
1701
Delay
(0 ... 100)
(0 ... 100)
1702
Output Relay A
(R3)
1703
Output Relay B
1704
Enable
(OFF / RUN / ON)
1705
Fail Class
(0.1 ... 300.0)
1706
Type
1710
Coolant Temp. & Cool. Level
(0 ... 100)
1711
Delay
(0.1 ... 300.0)
(R0 ... R3)
1712
Output Relay A
(R0 ... R3)
1713
Output Relay B
1714
Enable
1715
Fail Class
(1 ... 2250)
1716
Type
(0.2 ... 100.0)
1720
Low Fuel Switch
(R0 ... R3)
1721
Delay
(R0 ... R3)
1722
Output Relay A
(OFF / RUN / ON)
(Warning / Trip / Trip+Stop / Shutdown)
1723
Output Relay B
1724
Enable
1725
Fail Class
1726
Type
(1 ... 2250)
1730
Dig.Input 4 / GCB closed
1731
Delay
(0.0 ... 180.0)
1732
Output Relay A
(R0 ... R3)
(R0 ... R3)
1733
Output Relay B
(OFF / RUN / ON)
1734
Enable
1735
Fail Class
(Warning / Trip / Trip+Stop / Shutdown)
1736
Type
(0.0 ... 60.0)
1860
Run Status
1861
Delay
(R0 ... R3)
1862
Output Relay A
(R0 ... R3)
(OFF / RUN / ON)
1863
Output Relay B
(Warning / Trip / Trip+Stop / Shutdown)
1864
Enable
1870
W/L Input
1871
Delay
(0 ... 150.0)
(0.0 ... 600.0)
1872
Output Relay A
(R0 ... R3)
1873
Enable
1874
Type
(R0 ... R3)
(OFF / RUN / ON)
1880
Static Charger
(Warning / Trip / Trip+Stop / Shutdown)
(Low / High)
1881
Delay
1882
Output Relay A
1883
Enable
(0 ... 150.0)
1884
Type
(0.0 ... 600.0)
(R0 ... R3)
(R0 ... R3)
(OFF / RUN / ON)
(Warning / Trip / Trip+Stop / Shutdown)
(Low / High)
(0.0 ... 5.0)
(2 ... 10)
(1 ... 100)
(30.0 ... 990.0)
(ON / OFF)
SERVICE LEVEL
N/A
(0.0 ... 15.0)
5.0s
(0.0 ... 600.0)
R0
(R0 ... R3)
R0
(R0 ... R3)
OFF
(OFF / RUN / ON)
Warning
(Warning / Trip / Trip+
Low
(Low / High)
CUSTOMER LEVEL
N/A
(0 ... 100)
20.0s
(0.0 ... 100.0)
R0
(R0 ... R3)
R0
(R0 ... R3)
OFF
(OFF / RUN / ON)
Warning
(Warning / Trip / Trip+
SERVICE LEVEL
3.0s
(0.0 ... 100.0)
R0
(R0 ... R3)
R0
(R0 ... R3)
RUN
(OFF / RUN / ON)
Shutdown
(Warning / Trip / Trip+
Low
(Low / High)
SERVICE LEVEL
3.0s
(0.0 ... 100.0)
R0
(R0 ... R3)
R0
(R0 ... R3)
ON
(OFF / RUN / ON)
Shutdown
(Warning / Trip / Trip+
Low
(Low / High)
CUSTOMER LEVEL
3.0s
(0.0 ... 100.0)
R0
(R0 ... R3)
R0
(R0 ... R3)
ON
(OFF / RUN / ON)
Trip + Stop
(Warning / Trip / Trip+
High
(Low / High)
CUSTOMER LEVEL
10.0s
(0.0 ... 100.0)
R0
(R0 ... R3)
R0
(R0 ... R3)
OFF
(OFF / RUN / ON)
Warning
(Warning / Trip / Trip+
High
(Low / High)
SERVICE LEVEL
5.0s
(0.0 ... 60.0)
R0
(R0 ... R3)
R0
(R0 ... R3)
OFF
(OFF / ON)
SERVICE LEVEL
3.0s
(0.0 ... 100.0)
R0
(R0 ... R3)
RUN
(OFF / RUN / ON)
Low
(Low / High)
SERVICE LEVEL
10.0s
(0.0 ... 100.0)
R0
(R0 ... R3)
ON
(OFF / ON)
High
(Low / High)
2954 2100 01