SPECIFICATIONS

Capacity
Input 58,000 BTUs/Hour.
PMG-60
Output – 46,000 = 13.4kW
Input 105,000 BTUs/Hour.
PMG-100
Output – 84,800 = 24.8kW
Input 195,000 BTUs/Hour.
PMG-200
Output – 156,000 = 45.7kW
Fuel
All Models
Natural or Propane Gas
Electrical
PMG-60
120 VAC, 210 watt, 1.75 amps.
PMGH-60
120 VAC, 18 watt, 0.15 amps.
PMG-100/200
120 VAC, 360 watt, 3.00 amps.
Connections
1
Gas –
PMG-60
Electric – 120 VAC, 15 amp.
3
Gas –
PMG-100/200
Electric – 120 VAC, 15 amp.
Fluing
PMG-60
Direct – combustion air enters
bottom, flue gasses exit sides at
top of unit.
PMG-100/200
Direct – combustion air enters bottom,
flue gasses exit right side or back
at top of unit. 4" (102 mm) flue round.
Operating Water Pressure
150 PSI max. Relief valve set at
All Models
150 PSI, 210°F (99°C)
Shipping Weight
PMG-60
130 lbs. (59 kg) dry.
PMG-100
180 lbs. (82 kg) dry.
PMG-200
215 lbs. (98 kg) dry.
OPTIONS (NOT FOR RETROFIT)
K Stainless Steel Body, Base, and Sides
K Pressure Reducing Valves (Brass or Iron)
K 6"-7" (152-178 mm) Adjustable Stainless Steel Legs (4)
K Floor Mounting Hardware
K Security Package
PRODUCT SPECS
Gas Booster Water Heater
The Gas Booster Water Heater to supply the final 180°F (82°C)
rinse for the dishwasher shall be a Hatco Powermite
manufactured for commercial use by the Hatco Corporation,
Milwaukee, WI 53234 U.S.A.
With 24/7 service (U.S and Canada only), the booster shall have
the capacity to heat ....gph (lph) from 110°F to 180°F (43°C to
82°C) and it shall be rated at ....btu, 120 volts, single phase. The
stainless steel tank shall be designed for a working pressure of 150
psi (1034 kPa) and hydrostatically tested at 300 psi (2069 kPa).
The heater shall be complete with all internal plumbing, including
3
" NPT pipe and fittings from inlet and outlet. All controls shall
4
HATCO CORPORATION P.O. Box 340500 Milwaukee, WI 53234-0500 U.S.A. • (800) 558-0607 • (414) 671-6350
Fax (800) 543-7521 • Int'l. Fax (414) 671-3976 • www.hatcocorp.com • E-mail: equipsales@hatcocorp.com
Form No. PMG Spec Sheet
POW RMIT
Models PM -60, PM -100, PM -200
20
3
" (527 mm)
4
Alternate TPRV
Location
Electrical
25
1
"
4
(641 mm)
Gas
Water
Water
5
18
"
8
Inlet
Outlet
Inlet
(473 mm)
6" (152 mm)
6" (152 mm)
LEFT SIDE VIEW
3
" NPT, Water –
" NPT,
2
4
3
" NPT, Water –
" NPT,
4
4
®
Model ...., as
IT M#
®
G S BOOSTER W TER HE TERS
36" (914 mm) PMG-200
27
1
" (699 mm) PMG-100
20
3
"
(527 mm)
2
4
Electrical
Water Outlet
31"
Water
Water
Water Inlet
(787 mm)
Inlet
Outlet
Gas Inlet
RIGHT SIDE VIEW
FRONT VIEW
Models PMG-100 & PMG-200
DIMENSIONS
PMG-60: 20
3
/
"W x 24
1
/
"D x 24
8
2
1
3
PMG-100: 27
/
"W x 20
/
"D x 31"H* (699 x 527 x 787 mm).
2
4
PMG-200: 36"W x 20
3
/
"D x 31"H* (914 x 527 x 787 mm).
4
3
PMGH-60 Hood: 24
/
"W x 13
8
* Height includes 6" (152 mm) legs.
+
Add 4" (102 mm) for flue adapter.
• Adds 4" (102 mm) to width and 5
Gas Inlet Pressure
Gas Type
Minimum
Natural
5.0" (127 mm)
Propane/LP
11.0" (279 mm)
Operating Pressure Specifications at Manifold
Water Column At Pressure Tap
Gas Type
Natural
Propane/LP
Vent
^
PMGH-60
4" (102 mm) diameter vent pipe adapter
PMG-100/200
Forced draft system with 4" (102 mm)
diameter vent pipe adapter.
Before installing any method of venting you should contact the local code
^
authority or your gas supplier to make sure that the final installation will be
acceptable to the authorities who have jurisdiction.
The proper method of venting a power vented gas appliance is too
complicated to cover in this specification sheet and is explained in detail
in the National Fuel Gas Code. Before installing the venting system, the
person or agency making the installation must be familiar and experienced
with the guidelines of the National Fuel Gas Code.
ALL INSTALLATIONS MUST BE MADE BY A QUALIFIED
INSTALLER IN ACCORDANCE WITH THE NATIONAL
FUEL GAS CODE OR LOCAL CODES.
ACCESSORIES
K Exhaust Hood PMGH-60 (For PMG-60 only)
K High Altitude Orifice Kit
be built-in, and carry safety approval in accordance with
ANSI 21.10.3. Sanitary approval shall be in accordance with
NSF Standard 5. Proper surface mounting circuit breaker or fused
disconnect switch shall be provided by electrical contractor.
The gas fired heating system shall be controlled by close
tolerance immersion thermostats. The booster shall be protected
with high temperature limit switch (ECO) and low water cut-off.
The heater shall consist of stainless steel front, top, and stainless
steel adjustable legs or stainless steel front and silver-gray
hammertone sides and back with standard 6" (152 mm) legs.
The heater shall include a temperature/pressure relief valve,
high-temperature limit, pressure reducing valve with bypass,
indicating temperature/pressure gauge, shock absorber, and
blended phosphate water treatment system.
36" (914 mm) PMG-200
27
1
" (699 mm) PMG-100
2
Alternate
4" (102 mm)
Flue
TPRV
Vent Adapter
Location
25"
Water Outlet
(635 mm)
Gas
Water Inlet
Inlet
Gas Inlet
6" (152 mm)
REAR VIEW
5
/
"H* (518 x 622 x 625 mm).
8
+
3
7
/
"D
x 6
/
"H
(619 x 340 x 175 mm).
8
8
"
7
/
(149 mm) to height of PMG-60.
8
Water Column
Maximum
10.5" (267 mm)
13.0" (330 mm)
High Burn
3.5" ( 89 mm)
10.0" (254 mm)