Download Print this page

Specifications - Hatco C-12 Brochure & Specs

Electric booster water heater
Hide thumbs Also See for C-12:

Advertisement

E L E C T R I C
B O O S T E R W A T E R H E A T E R
IMPERIAL BOOSTER HEATER
23" (584 mm)
3
" NPT
4
Coupling for
Temperature/
Pressure Relief Valve
31
3
"
8
11
9
"
(797 mm)
16
(246 mm)
1
22
"
16
(560 mm)
2" (51 mm)
3
" NPT NIPPLE
4
180ºF (82ºC) OUTLET
3
" NPT TEE FOR
4
140ºF (60ºC) WATER INLET,
INSTALL DRAIN VALVE OTHER END
SIDE VIEW
Model
kW
Shipping Weight
S-6*
6
200 lbs. (91 kg)
S-7*
7
200 lbs. (91 kg)
S-9*
9
200 lbs. (91 kg)
S-12
12
200 lbs. (91 kg)
S-13
13.5
200 lbs. (91 kg)
S-15
15
200 lbs. (91 kg)
S-17
17.25
200 lbs. (91 kg)
S-18
§
18
200 lbs. (91 kg)
COMPACT (4-18kW) BOOSTER HEATER
26" (660 mm)
3
20
" (527 mm)
4
OUTLET
3
" NPT
4
Coupling for
3
19
"
4
Temperature/Pressure
(502 mm)
Relief Valve
INLET
Electical connection
3
from side or below
SIDE VIEW
COMPACT (24-58kW) BOOSTER HEATER
30
1
/
" (775 mm)
2
24" (610 mm)
OUTLET
3
" NPT
4
Coupling for
18"
Temperature/Pressure
(457 mm)
Relief Valve
INLET
Electical connection
from side or below
SIDE VIEW
COMPACT (4-18kW)
Model
kW
Shipping Weight
C-4
4
105 lbs. (48 kg)
C-5
5
105 lbs. (48 kg)
C-6*
6
118 lbs. (54 kg)
C-7*
7
118 lbs. (54 kg)
C-9*
9
118 lbs. (54 kg)
C-12
12
120 lbs. (54 kg)
C-13
13.5
120 lbs. (54 kg)
C-15
15
120 lbs. (54 kg)
C-17
17.25
120 lbs. (54 kg)
C-18
§
18
120 lbs. (54 kg)
VOLTAGE: Available in 208, 240, and 480 volts. Export voltages available, consult factory.
* Only 6, 7, & 9kW Models, 208 and 240V only,
can be field converted to single phase (units are
shipped 3-phase open delta). Larger branch circuit
required than for balanced 3-phase of equal kW.
(Balanced 3-phase available, consult factory.)
17.25kW models available in 208V 3-phase only.
18kW models not available in 208V 3-phase.
§
P.O. Box 340500
Milwaukee, WI 53234-0500 U.S.A.
(800) 558-0607 (414) 671-6350
Fax: (800) 543-7521 Int'l. Fax: (414) 671-3976
www.hatcocorp.com
E-mail: equipsales@hatcocorp.com
Printed in U.S.A.
23
1
" (597 mm)
2
3
25
"
8
(645 mm)
3
9
"
4
(248 mm)
2"
(51 mm)
6" (152 mm)
4" (102 mm)
Electical connection
from below
REAR VIEW
Model
kW
Shipping Weight
S-24
24
214 lbs. ( 97 kg)
S-27
27
214 lbs. ( 97 kg)
S-30
30
214 lbs. ( 97 kg)
S-36
36
214 lbs. ( 97 kg)
S-39
39
214 lbs. ( 97 kg)
S-40
40.5
224 lbs. (102 kg)
S-45
45
224 lbs. (102 kg)
••
S-54
54
224 lbs. (102 kg)
••
S-58
58.5
224 lbs. (102 kg)
13" (330 mm)
1
6
" (165 mm)
2
3
"
4
(19 mm)
7
7
"
8
3
1
13
"
2
1
"
4
2
"
4
4
(200 mm)
(349 mm)
(57 mm)
(6 cm)
1
3
"
2
(89 mm)
6" (152 mm)
" NPT Nipple
4
REAR VIEW
18" (457 mm)
6"
(152 mm)
7
7
"
8
3
3
1
1
/
"
"
2
1
/
"
12"
(200 mm)
1
4
4
2
4
"
4
(8 cm)
(83 mm)
(57 mm)
(6 cm)
(305 mm)
2"
(51 mm)
3
" NPT Nipple
6" (152 mm)
4
REAR VIEW
COMPACT (24-58kW)
Model
kW
Shipping Weight
C-24
24
142 lbs. (64 kg)
C-27
27
142 lbs. (64 kg)
C-30
30
142 lbs. (64 kg)
C-36
36
142 lbs. (64 kg)
C-39
39
142 lbs. (64 kg)
C-45
45
142 lbs. (64 kg)
••
C-54
54
142 lbs. (64 kg)
••
C-58
58.5
142 lbs. (64 kg)
• Not available in 208V single phase.
•• Not available in 208V or 240V single phase.
480V available in single phase only.
Available in 10.5kW, consult factory for details.
Balanced 3-phase.
Open delta on 3-phase. Larger circuit required
than for balanced 3-phase of equal kW.
S P E C I F I C A T I O N S
MINI-COMPACT
SPECIALTY HEATER
3
11
" (298 mm)
4
1
12
2
(318 mm)
6" (152 mm)
Electical connection
from below
FRONT VIEW
Model
kW
Phase
MC-10
9.9
1 or 3
MC-11
11.4
1 or 3
VOLTAGE: Available in 208, 240, and 480 volts.
3CS2 HYDRO-HEATER SANITIZING SINK HEATER
1
17
" (433 mm)
16
1
5
"
2
(140 mm)
8
1
" (216 mm)
2
3
" hose
4
connection
1
3
" &
" Conduit K.O.
to drain
2
4
SIDE VIEW
Model
kW
Phase
3CS2-3
3
1
15" (381 mm) Sq. or less
3CS2-4
4
1
16"-18" (406-457 mm) Sq.
3CS2-6
6
1
19"-21" (483-533 mm) Sq.
3CS2-3B
3
3
15" (381 mm) Sq. or less
3CS2-4B
4
3
16"-18" (406-457 mm) Sq.
3CS2-6B
6
3
19"-21" (483-533 mm) Sq.
3CS2-9B
9
3
21"-25" (533-635 mm) Sq.
VOLTAGE: 208 or 240 volts, 50/60 Hz standard.
3CS THIRD COMPARTMENT SINK HEATER
A
B
C
5
12
"
8
(321 mm)
SIDE VIEW
Model
kW
Phase
3CS-3
3
1
15" (381 mm) Square or less
3CS-4
4.5
1
16"-18" (406-457 mm) Sq.
3CS-6
6
1 or 3
19"-21" (483-533 mm) Sq.
3CS-9
9
1 or 3
21"-25" (533-635 mm) Sq.
3CS-3B
3
3
15" (381 cm) Square or less
3CS-4B
4.5
3
16"-18" (406-457 mm) Sq.
3CS-6B
6
3
19"-21" (483-533 mm) Sq.
3CS-9B
9
3
21"-25" (533-635 mm) Sq.
Model
A
B
7
1
16
"
5
"
8
2
1- or 3-phase
(429 mm)
(140 mm)
17
1
"
4
5
"
8
8
Bal. 3-phase
(435 mm)
(117 mm)
VOLTAGE: Available in 208 and 240 volts, 50/60 Hz. 480 volt and CSA wiring for Canada
available. Export voltages available.
7
12
" (327 mm)
8
5
7
"
16
3
"
4
(138 mm)
NPT
Nipple
OUTLET
13
2
"
16
3
" NPT
4
(71 mm)
Coupling for
1
"
18
"
2
Temperature/
(470 mm)
Pressure
Relief Valve
INLET
3
" NPT Nipple
4
SIDE VIEW
Voltage
Shipping Weight
208 volts
48 lbs. (22 kg)
240 volts
48 lbs. (22 kg)
3
6
"
4
1
(171 mm)
3
"
16
(78 mm)
3
3
" (86 mm)
1"
8
(25 mm)
2
5
"
8
(67 mm)
3
12
"
8
1
3
" &
"
(314 mm)
2
4
3
9
"
Conduit K.O.
4
(247 mm)
REAR VIEW
Sink Area
Shipping Weight
24 lbs. (11 kg)
24 lbs. (11 kg)
27 lbs. (12 kg)
24 lbs. (11 kg)
24 lbs. (11 kg)
27 lbs. (12 kg)
27 lbs. (12 kg)
1"
E
D
F
(25 mm)
2
7
" (73 mm)
8
3
"
4
3
3
" hose
9
"
Conduit
4
4
connection
(248 mm)
K.O.
to drain
4" (102 mm)
REAR VIEW
Sink Area
Shipping Weight
24 lbs. (11 kg)
24 lbs. (11 kg)
27 lbs. (12 kg)
27 lbs. (12 kg)
30 lbs. (14 kg)
30 lbs. (14 kg)
30 lbs. (14 kg)
30 lbs. (14 kg)
C
D
E
1
7
3
8
"
2
"
6
"
3
2
8
4
(216 mm)
( 73 mm)
(171 mm)
( 86 mm)
8
1
"
4"
8"
2
(216 mm)
(102 mm)
(203 mm)
(102 mm)
Form No. EWHB-2004
February 2004
F
3
"
8
4"

Advertisement

loading