2) Check for continuity by a multimeter as shown in Fig.2.
7.CAPACITOR
1) Remove the lead wires from the capacitor terminals, and then place a probe on the
capacitor terminals as shown in Fig.3.
2) Observe the deflection of the pointer, setting the resistance measuring range of the
multimeter to the maximum value.
* The capacitor is "good" if the pointer bounces to a great extent and then gradually returns to
its original position.
* The range of deflection and deflection time differ according to the capacity of the capacitor.
O
M
P
O
N
E
N
T
S
O
M
P
O
N
E
N
T
S
Fuse
PCB Ass'Y
Fuse
Fig.2
Compressor motor
capacitor
Fig.1
Fan motor
capacitor
77
Multimeter
Fig.3