Opening A Com (Console) Session; Optional: Configuring Remote Auto Install; Configuring Rai For Frame Relay - Enterasys X-Pedition XSR-3150 Getting Started Manual

X-pedition security router
Hide thumbs Also See for X-Pedition XSR-3150:
Table of Contents

Advertisement

• Router ports and protocol stacks are initialized based on startup configuration.
• Alarms and messages reported during initialization are logged.
• COM is up.
• The XSR is up.
To view the screen output produced when the XSR reboots, refer to
Characteristics"

Opening a COM (Console) Session

1.
Open a COM session to the XSR using Procomm or another program.
Set the session properties as follows: BPS - 9600, Data bits - 8, Parity - none, Stop bits - 1, Flow
control - none. Refer to
2.
When the XSR login appears, enter admin and enter no (blank) password. Note that logins
and passwords can be changed later.
3.
Optionally, you can use the COM port as a serial interface in a dial backup capacity. Refer to
"Setting Up the Backup Line"
4.
Another option is to run the Remote Auto Install (RAI) program which permits you to
automatically perform first-time basic configuration of an XSR in the field or maintain central
management after it is placed in production.
Refer to the following section for quick configuration of RAI. For a full description of RAI
including how it works, refer to "Chapter 2: Managing the XSR" in the XSR User's Guide.

Optional: Configuring Remote Auto Install

In short, the RAI application transports a startup configuration file from a TFTP server for use in
configuring the remote XSR. This file is placed in the
executed via the normal startup process. RAI is supported on a Frame Relay network running on a
serial NIM card (configuration example shown below), RAI over Ethernet (with DHCP), RAI PPP
over a Leased line or RAI over an ADSL network.
For remote XSR setup, you need only hook up cabling as described in "Chapter 2: Hardware
Installation" of this guide.

Configuring RAI for Frame Relay

To configure two remote XSRs with RAI over Frame Relay, perform the following setup on the
central site. On multi-point Serial sub-interface 1/0.1, configure DLCIs 16 and 18 to statically map
only the first error will be reported, along with a count of the sum of errors incurred. In the
case of a single error, only the error line will be reported. Error messages will be logged as
well. Because the result of continuing to process a flawed startup-config is not predictable,
the nature and position of the syntax error may cause the erroneous configuration of the
XSR.
on page 3-33.
"Initialization Output"
Note: You can abort RAI at any time by pressing any key.
on page 3-33 to view XSR initialization data.
on page 3-16.
Flash:
Opening a COM (Console) Session
"XSR Rebooting
directory as the
startup-config
XSR Getting Started Guide 3-3