TABLE 16: DR180 BLOWER PERFORMANCE - STANDARD DRIVE (GAS HEAT)
ESP CFM RPM
KW
BHP CFM RPM
0.2
6246
912 3.276 3.93 6049
0.4
5893
914 3.037 3.65 5667
0.6
5498
916 2.783 3.34 5257
0.8
5101
918 2.548 3.06 4814
1.0
4672
919 2.324 2.79 4347
1.2
4183
921 2.087 2.51
1 turn
6500
1 Turn
2 Turns
6000
3 Turns
5500
4 Turns
5 Turns
5000
6 Turns
4500
0
Unitary Products Group
15 ton Standard Drive Blower Performance (Horizontal Discharge)
KW
BHP CFM RPM
881 2.997 3.60 5705
851 2.611 3.13 5479
882 2.777 3.33 5301
852 2.364 2.84 5055
883 2.486 2.98 4916
853 2.124 2.55 4610
885 2.298 2.76 4443
856 1.917 2.30 4124
887 2.129 2.55 3929
857 1.714 2.06 3526
2 turns
3 turns
15-Ton Standard Drive
VP56 X BK105
0.2
0.4
External Static ("WC)
KW
BHP CFM RPM
KW
BHP CFM RPM
818 2.367 2.84 5225
819 2.163 2.60 4757
820 1.938 2.33 4287
821 1.705 2.05 3818
823 1.502 1.80 3112
4 turns
0.6
0.8
KW
BHP CFM RPM
785 2.111 2.53 4979
754 1.822 2.19
786 1.893 2.27 4505
755 1.628 1.95
788 1.699 2.04 3999
757 1.435 1.72
789 1.511 1.81 3368
758 1.210 1.45
791 1.235 1.48 2612
759 0.967 1.16
5 turns
6 turns
1
1.2
KW
BHP
1.4
41