8.16. Remove the Hanger metals and
the Stand brackets
1. Remove the Plasma panel section from the servicing
stand and lay on a flat surface such as a table (covered
by a soft cloth) with the Plasma panel surface facing
downward.
2. Remove the Support metal. (See section 8.15.)
3. Remove the Hanger metals (L, R) fastening screws (×6
each) and remove the Hanger metals (L, R).
4. Remove the Stand brackets (L, R) fastening screws (×4
each) and remove the Stand bracket covers (L, R)
and the Stand brackets (L, R).
8.17. Remove the C1-Board
1. Remove the Control button unit. (See section 8.8.)
2. Remove the Hanger metal R and Stand bracket R. (See
section 8.16.)
3. Remove the flexible cables holder fastening screws (×10
).
4. Disconnect the flexible cables (CB1, CB2, CB3, CB4 and
CB5).
5. Disconnect the flexible cable (C10).
6. Disconnect the connector (C14).
7. Remove the screws (×5
8.18. Remove the C2-Board
1. Remove the Support metal. (See section 8.15.)
2. Remove the flexible cables holder fastening screws (×10
).
3. Disconnect the flexible cables (CB6, CB7, CB8, CB9 and
CB10).
4. Disconnect the flexible cables (C20, C21, C22 and C26).
5. Remove the screws (×5
23
) and remove the C1-Board.
) and remove the C2-Board.