<When the installation plate is directly
mounted on the wall>
1. Securely fit the installation plate onto the wall by
screwing it in the upper and lower parts to hook
up the indoor unit.
2. To mount the installation plate on a concrete wall
with anchor bolts, use the aanchor bolt holes as
illustrated in the below figure.
3. Install the installation plate horizontally in the wall.
CAUTION
When installing the installation plate with mounting
screw, do not use the anchor bolt holes.
Otherwise, the unit may fall down and result in
personal injury and property damage.
Installation plate
<Keep horizontal direction>
Fig. 10-3-4
5 mm dia. hole
Clip anchor
(local parts)
Fig. 10-3-5
CAUTION
Failure to firmly install the unit may result in
personal injury and property damage if the
unit falls.
• In case of block, brick, concrete or similar type
walls, make 5 mm dia. holes in the wall.
• Insert clip anchors for appropriate mounting screws
NOTE :
• Secure four corners and lower parts of the
installation plate with 4 to 6 mounting screws
to install it.
Anchor bolt
Projection
15mm or less
7 Mounting screw
Ø4 × 25
l
– 53 –
FILE NO. SVM-12071
10-3-3. Wiring Connection
<How to connect the connecting cable>
Wiring the connecting cable can be carried
out without removing the front panel.
1. Remove the air inlet grille. Open the air inlet
grille upward and pull it toward you.
2. Remove the terminal cover and cord clamp.
3. Insert the connecting cable (according to the
local rule) into the pipe hole on the wall.
4. Take out the connecting cable through the cable
slot on the rear panel so that it protrudes about
15 cm from the front.
5. Insert the connecting cable fully into the terminal
block and secure it tightly with screws.
6. Tighten firmly but not over 1.2 N·m (0.12 kgf·m)
7. Secure the connecting cable with the cord clamp.
8. Fix the terminal cover, rear plate bushing and
air inlet grille on the indoor unit.
CAUTION
CAUTION
• Be sure to refer to the wiring system diagram
labeled inside the front panel.
• Check local electrical cords and also any specific
wiring instructions or limitations.
Cord clamp
Screw
Terminal cover
Screw
Connecting cable
Stripping length of the connecting cable
NOTE :
Use stranded wire only.
Wire type : More than 1.5 mm
60254 IEC66) or 1.3 mm
Terminal block
Earth line
Connecting cable
Fig. 10-3-6
Fig. 10-3-7
2
(H07RN-F or
2
(AWG-16)