Toshiba RAS-18N3KV-E Service Manual page 21

Split type
Table of Contents

Advertisement

RAS-22N3KV-E / RAS-22N3AV-E
P
Pressure measurement
Gauge attaching port
Vacuum pump connecting port
Deoxidized copper pipe
Outer dia. : 12.7mm
Thickness : 0.8mm
4-way valve
(STF- 0213-Z )
Accumulater tank
NOTE :
• The maximum pipe length of this air conditioner is 15m. When the pipe length exceeds 15m, the additional
charging of refrigerant, 20g per 1m for the part of pipe exceeded 15m is required. (Max. 100g)
INDOOR UNIT
Indoor heat
exchanger
Cross flow fan
Deoxidized copper pipe
Outer dia. : 6.35mm
Thickness : 0.8mm
Sectional shape
of heat insulator
Muffler
Muffler
TD
Compressor
DA150A1F-20F
TS
TO
Split capillary
1 -dia. 2 × 100
Outdoor heat
2 - 4 -dia. 2 × 66
exchanger
1
2
3
4
TE
Propeller fan
OUTDOOR UNIT
20
FILE NO. SVM-12071
T1 Temp. measurement
TC
TA
Strainer
Pulse Modulating valve
at liquid side
(CAM-BD16TCTH-2)
Distributor
Refrigerant amount: 1.40kg
NOTE:
Max.
: 20m
Min.
: 2m
Chargeless : 15m
Charge
: 20g/m
(16 to 20m)
Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)