Temperature Status Led - Motorola RFS6000 Series Installation Manual

Rfs6000 series switch
Table of Contents

Advertisement

System Status 1 LED
Green Blinking
Green Blinking
Green Solid
3.1.4
Fan LED
Fan LED
Off
Green Blinking
Green Solid
Amber Solid
Amber Blinking
3.1.5

Temperature Status LED

Temperature LED
Off
Green Solid
Amber Solid
System Status 2 LED
Green Solid
Alternating Green Blinking
& Amber Blinking
Amber Blinking
Event
System Off / POST Start
POST in Process
All System Fans Normal Operation
Redundant Cooling Failure
System Operational
System Cooling Failure
System will be held in reset until the issue is
resolved
Event
System Off
Ambient Inlet Temperature is within specified
operating limit
Ambient Inlet Temperature is near the maximum
operating temperature
During switch start up this LED will be lit Solid
Amber. This is normal behavior and does not
indicate an error.
Event
Redundant System failed over and adopting
ports
Redundant System not failed over.
No License to adopt Access Ports
or
No Country Code configured on the switch
or
License and Country Code configured, but no
APs adopted
LED Codes
6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents