Baxi Combi Instant 80e Installation & Servicing Instructions Manual page 52

Gas fired wall mounted combination boiler
Table of Contents

Advertisement

Gas Tap
Fig. 1
4
Fig. 2
Heating Flow, Heating Return
and Mains Water Inlet
Isolating Valves
1.0 Warnings
1.1
In an Emergency
If a water or gas leak occurs or is suspected, the
boiler can be isolated at the inlet valves as
follows;
1. Turn off the electrical supply and turn the
selector switch on the facia box to the OFF
position.
2. Using a suitable open ended spanner or
screwdriver turn the square on the gas tap to the
left to isolate the gas supply at the boiler (Fig. 1).
3. The isolating valves are positioned under the
boiler and can be closed by turning their taps to
the right towards the wall (Fig. 2).
4. Call your installer or Service Engineer as soon
as possible.
1.2
In case of gas leaks
1. If a gas leak is found or suspected, turn off the
gas supply at the meter immediately and at the
isolating valve on the boiler if possible. Contact
your Gas Supplier immediately.
1.3
Servicing your Appliance
1. For reasons of safety and economy your
appliance should be serviced annually. Servicing
must be performed by a competent person. Your
installer or Service Engineer will be able to advise
you.
2. Any purpose provided ventilation should be
checked periodically to ensure that it is free from
obstruction.
1.4
Electricity Supply
1. THIS APPLIANCE MUST BE EARTHED.
2. A standard 230V ~ 50Hz supply is required.
The appliance must be protected by a 3 amp
fuse.
Never Hang Flammable Items Over The
Appliance