Raymarine p70 User Reference page 46

Pilot controller
Table of Contents

Advertisement

Alarm name
Alarm type
SeaTalk fail
Safety Alarm
EEPROM
Safety Alarm
corruption
No Pilot
Safety Alarm
No Compass
Safety Alarm
46
Description
Action
Total SeaTalk
• Check
data transmission
connections
problem.
for short or
open circuit.
• Check system
for device
fault.
• Pilot drops to
standby and
alarm times
out after 10
seconds.
A corruption
• Pilot drops to
of critical
standby and
configuration
alarm times
data has
out after 10
occurred.
seconds.
The Pilot
• Check Seatalk
controller has lost
or Seatalk
communications
bus wiring
with the course
between SPX
computer;
and Pilot
this alarm is
controller.
generated by the
• Check that
Pilot controller.
the course
computer is
powered up.
Compass is not
• Check
connected.
connections
and compass
transducer.
Alarm name
Alarm type
Rate Gyro fault
Safety Alarm
Current Limit
Safety Alarm
Rudder
Safety Alarm
ng
reference unit
failure
Description
Action
The gyro sensor
• Internal
has failed.
Gyro failure,
investigate
fault and
Consult a
Raymarine
Service Agent.
Drive overload
• Check drive
current
unit and
exceeded.
connections
for stall or
short circuit
wiring
• Pilot drops to
standby and
alarm times
out after 10
seconds.
Rudder
• Pilot drops to
Reference
standby and
connection has
alarm times
been lost, or
out after 10
exceeded it's
seconds.
limits.
Rudder reference
transducer has
failed while in
auto. Angle
is more than
50 degrees or
connection to
rudder reference
is lost