3 Commissioning
Buttons on the BOP-2
Panel/Button
Function
Indicates
Start motor
Stop motor
Manual
Automatic
Functions
Access
parameters
Increase
Decrease
Figure 3-6
Buttons on the BOP-2
40
The LCD displays the settings currently used by the converter.
Status
Pressing the button starts the converter. This button is disabled by
default. To enable this button set P0700 = 1.
OFF1 Pressing the button causes the motor to come to a standstill
at the selected ramp down rate. Disabled by default; to
enable set P0700 = 1.
OFF2 Pressing the button twice (or once long) causes the motor to
coast to a standstill.
This function is always enabled.
The customer terminal strip (CD S0) and the operating panel (BOP-
mode
2) are sources for commands and set values
The customer's terminal strip (CD S1) or the serial (US S) or field bus
interface (e.g. PROFIBUS) are sources for commands and set
mode
values.
This button can be used to view additional information.
Pressing and holding the button for 2 seconds from any parameter
during operation, shows the following:
1.
DC link voltage (indicated by d – units V).
2.
Output current. (A)
3.
Output frequency (Hz)
4.
Output voltage (indicated by o – units V).
5.
The value selected in P0005 (If P0005 is set to show any of the
above (1 - 4) then this will not be shown again).
Additional presses will toggle around the above displays.
Jump Function
From any parameter (rXXXX or PXXXX) a short press of the Fn
button will immediately jump to r0000, you can then change another
parameter, if required. Upon returning to r0000, pressing the Fn
button will return you to your starting point.
Quit
In case of a fault or alarm the
message on the operator panel display.
Pressing this button allows access to the parameters.
Pressing this button increases the displayed value.
value
Pressing this button decreases the displayed value.
value
Effects
button resets the fault or alarm