Finishing; Non-Combustible Materials; Combustible Materials; Hearth Extension - Heatilator A36C Owner's Manual

Wood burning fireplace
Hide thumbs Also See for A36C:
Table of Contents

Advertisement

11

Finishing

A. Non-Combustible Materials
Materials which will not ignite and burn, composed of
any combination of the following:
-
Steel
- Iron
-
Brick
- Tile
-
Concrete
- Slate
-
Glass
- Plasters
Materials reported as passing ASTM E 136, Standard
Test Method for Behavior of Metals, in a Vertical Tube
Furnace at 750° C
B. Combustible Materials
Materials made of or surfaced with any of the following
materials:
-
Wood
- Compressed paper
-
Plant fibers
- Plastic
Any material that can ignite and burn; flame proofed or
not, plastered or un-plastered
C. Hearth Extension
WARNING! Risk of fire! High temperatures, sparks,
embers or other burning material falling from the fireplace
may ignite flooring or concealed combustible surfaces.
Protective metal hearth strips MUST be installed
(Section 7.C.).
Hearth extensions MUST be installed exactly as
specified.
Table 11.1
R = 1/k x inches of thickness
Table 11.2
Hearth Extension Insulation Alternatives-Total minimum R Value must equal 1.03
Material
Hearth & Home HX3, HX4 (Micore 300™)
USG Micore 160™
USG Durock™ Cement Board
Cement Mortor
Common Brick
Ceramic Tile
Armstrong™ Privacy Guard Plus
Marble
k per inch
r per inch
thick
0.49
0.39
1.92
5.0
5.0
12.50
0.46
14.3-20.0
Heatilator • A36C & A42C • 28396 • Rev AQ • 10/12
You MUST use a hearth extension with this fireplace.
This fireplace has been tested and approved for use with
a hearth extension insulated to a minimum R value of
1.03.
The hearth extension material MUST be covered with
tile, stone or other non-combustible material.
Manufactured hearth materials will usually have a
published R value (resistance to heat) or k value
(conductivity of heat). Refer to the formula in Table 11.1
to convert a k value to an R value,
Refer to Table 11.2 for hearth extension insulation
alternatives.
Hearth Extension Dimensions
Model #
in.
A36
(HX3)
mm
in.
A42
(HX4)
mm
Figure 11.1 Hearth Extension Dimensions
Minimum
thickness
thick
required
2.06
1/2 in.
2.54
1/2 in.
0.52
2 in.
0.20
5-1/8 in.
0.20
5-1/8 in.
0.08
12-1/4 in.
2.18
1/2 in.
0.07-0.05
14-5/8 in. - 20-3/8 in.
C
A
C
B
A
B
52
16
1321
406
203
66
20
12
1676
508
305
C
8
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

A36chA42chA42c

Table of Contents