E. Locating Fireplace & Chimney
Location of the fireplace and chimney will affect perfor-
mance.
Install through the warm airspace enclosed by the
building envelope. This helps to produce more draft,
especially during lighting and die-down of the fire.
Penetrate the highest part of the roof. This minimizes
the effects of wind loading.
Locate termination cap away from trees, adjacent
structures, uneven roof lines and other obstructions.
Minimize the use of chimney offsets.
Consider the fireplace location relative to floor and ceiling
and attic joists.
Take into consideration the termination requirements in
Section 8 and Section 9.
NOTICE: Locating the fireplace in a basement or in a location
of considerable air movement can cause intermittent smoke
spillage from fireplace. Do not locate fireplace near
frequently open doors
central heat outlets or returns
Location NOT recommended:
• Not the highest point of the roof
• Wind loading possible
Windward
Figure 5.2
Recommended Chimney Locations
16
Recommended Location:
• Above peak
Recommended Location:
• Inside heated space
• Above peak
Marginal Location:
• Below peak
Recommended:
• Insulated exterior chase
in cooler climates
Multi-level Roofs
Heatilator • A36C & A42C • 28396 • Rev AQ • 10/12
Marginal Location:
• Wind loading possible
Location NOT recommended:
• Too close to tree
• Below adjacent structure
• Lower roof line
• Avoid outside wall
Leeward