■ Mechanical disassemblies

Disassemble should be made following procedures in numerical order.
Following steps show the basic procedures, therefore unnecessary step may be ignored.
Caution:
The parts and screws should be placed exactly the same position as the original other-
wise it may cause lose of performance and product safety.
The wiring method of the leads and ferrite cores should be returned exactly the same
state as the original, otherwise it may cause lose of performance and product safety.
1
Lamp Unit and Alarm Battery removal.
1. Remove the screw-A(M3x8) and remove the Lamp cover.
2. Loosen the 2 screws-B and remove the Lamp uint.
3. Remove the screw-C (M3x8) and remove the Battery cover.
4. Remove the Battery.
5. Remove the Air Filter upward.
Lamp Cover
Lamp Unit
Air Filter
- 15 -
(Type
T type
Tapping screw
C
A
B
Screws Expression
) mm
Diameter x Length
M Type
Machine screw
Battery Cover
Battery