Konica Minolta Bizhub 20p Service Manual page 188

Hide thumbs Also See for Bizhub 20p:
Table of Contents

Advertisement

(3) Remove the three bind B M4x12 Taptite screws and cup S M3x6 Taptite screw, and then
remove the Main shield plate ASSY.
aptite, bind B M4x12
aptite, bind B M4x12
aptite, cup S M3x6
Main shield plate ASSY
Frame L
Fig. 5-49
Assembling Note:
• Hang the Tip of the Switch arm spring of the Main shield plate on the Eject gear 28
sector.
Eject gear 28 sector
Main Shield Plate ASSY
Switch arm spring
Fig. 5-50
5-44
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents