Refractory Installation; Door Installation; Door Adjustment - Lennox BRENTWOOD SP Installation And Operation Instructions Manual

Epa wood-burning fireplaces
Table of Contents

Advertisement

REFRACTORY REPLACEMENT
The intense heat of the fire will normally cause
hairline cracks in the refractory. These cracks
can be minimized by proper curing as described
in "First Fires". They will not normally dimin-
ish the effectiveness of the refractory. If large
cracks develop, then the refractory should be
replaced. To replace the refractory bricks, fol-
low these steps:
1. Remove the front refractories
2. Remove the bottom refractory
3. Remove the left side refractory
4. Remove the right side refractory
5. Remove the back refractory
6. Remove the front ceramic baffle
7. Remove the rear ceramic baffle
To install the new refractories, follow the above
steps in reverse.

DOOR INSTALLATION

The door must be installed only when the installation of the Brentwood™
is completed. All you have to do is fit the male part of the hinge, already
on the door, to the female part, which is on the fireplace.
To remove the door, simply pull the door up from the hinges.
The door adjustment has been set at the factory. If the fit is still not
perfect, you can adjust the door using the hinge screws.
Figure 4
6
Figure 3
Door Installation
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
3
2

DOOR ADJUSTMENT

The door may need to be adjusted to be completely airtight. The gaskets'
air-tightness can be adjusted using the adjustment screw located on the
right side of the fireplace facade (An Allen key #1/8 – not supplied - will
be necessary for this adjustment).
Checking Door Seal
A one-inch strip of paper may be used to perform a test of the integrity
of the door seal. Close the door on the paper in at least eight points. It
is normal to feel only a slight amount of friction. The door gasket does
not need to be "tight" in all areas, since a small amount of leakage is not
hazardous or detrimental to the performance of your fireplace.
• Use only a Lennox Hearth Products glass doors,
specifically designed for the Brentwood fire-
place.
• The fireplace cannot be operated without a door.
Consult your dealer to select the correct door
model.
• Important! To assure proper alignment of glass
doors: Install this fireplace in a square and
plumb condition, using shims as necessary at
sides and/or bottom.
7
6
5
1
WARNINGS
4

Hide quick links:

Advertisement

Table of Contents
loading