Technical Information
5.15
Heater Relays - Access
The Heater Relays are secured to single bracket. The bracket is secured
to the frame near the 3 o'clock position of the drum.
1. Open the Front Service Panel – Refer to Section 5.3.
2. Remove the screw securing the bracket to the frame.
3. Pull the bracket away from the frame to access the relay(s).
Figure 5-12: Heater Relays with Bracket
W1900 Series Clothes Washers
48