Imbalance Monitoring; Motor Circuit - Miele W1903 User Manual

W1900 series clothes washers
Hide thumbs Also See for W1903:
Table of Contents

Advertisement

W1900 Series Clothes Washers
4.16

Imbalance Monitoring

Range 1
Range 2
Range 3
Range 4
Table 4-2: Imbalance Monitoring
4.17

Motor Circuit

A
Change Field Relay (spin/ wash actuation)
B
Motor Direction Relay
C
Temperature Limiter
D
Field Windings
E
Rotor Windings
F
Tachogenerator
Figure 4-7: Motor Circuit
0-0.7 kg
No reduction in spin speed.
If imbalance exists after 3 attempts to
redistribute the load then the spin speed is
0.7-1.1 kg
limited to 2
by model number)
If imbalance exists after 3 attempts to
redistribute the load then the spin speed is
1.1-2.0 kg
limited to 3
model number)
Load distribution attempts continually made
> 2 kg
until imbalance is reduced or the program time
has completed.
33
Technical Information
nd
highest value (exact rpm varies
rd
highest value (exact rpm varies by

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

W1918W1930W1966W1986W1926W1930i

Table of Contents