6.2

Measuring the temperature sensor

If a failure at the temperature sensor is assumed, the resistance can be checked by means of an
ohmmeter.
The resistance of the temperature sensor should be 500 – 600 ohms at room temperature.
Make sure to measure the insulation resistance between the metallic housing and each connection
terminal.
The resistance should be higher than 2 MOhms.
Fig. Measuring the temperature sensor
6.3

Demo mode

Not provided
6.4

Factory test / door lock test

Not provided
DGS-TDS-N 05.09 A. B. © Electrolux