Empire Heating Systems 3588-4 Installer And Serviceman's Manual page 8

Floor furnace
Table of Contents

Advertisement

*Dotted lines show the gas valve and flue collar for Model No. 3588 only. (Same side)
Register
width
Model No.
A
3588
22 3/4
5088
24 3/4
7088
32 3/4
Floor joists are on 16-inch centers. If you cut away one joist, the
next two are then on 32-inch centers. Because of the thickness of
the joists, that means there is about 30 1/2 inches of space between
them—just enough for the biggest floor furnace, Model 7088, which
is 30 inches wide. The smaller furnaces will need an additional sup-
port along the one side, or on both sides if you are centering the
32186-0-0513
Register
Casing
Casing
length
width
length
B
C
34 3/4
20
36 3/4
22
36 3/4
30
Figure 10
Figure 11
Overall
Floor to
height
Flue C.
D
E
32
24
15 1/4
34
26
16 3/4
34
27
15 1/4
furnace between two joists because location is critical. see Figure
10. If the location is not critical, it is easier for you to put the furnace
against a joist and then fill in with one additional support.
Floor to
Floor to
shield
gas inlet
F
G
10 1/2
18 1/2
12 3/4
20 1/4
12 3/4
20 1/4
Flue C.
size
H
I
4 D.
4 D.
5 D.
Page 8