Enrolling User Codes into the 2 Way receiver
The 2 way receiver must be "taught" the User code which will represent each KeyFob to be used on the system. This allows the
receiver to uniquely identify each KeyFob and log KeyFob opening and closing activity in the control panel's event buffer as well
as report openings and closings by KeyFob user if desired.
Note: Before proceeding, a 4 digit User Code representing each KeyFob must be programmed into the control panel.
1
Arm system from any keypad
2
Disarm system from any keypad
3
Enter Unique Code 1113 [ON/OFF] / [STAY]
4
Enter 4 digit User Code to represent KeyFob # 1, press [ON/OFF] / [AWAY]
5
Reenter the 4 digit User Code for KeyFob # 1, press [ON/OFF] / [OFF]
...
Repeat steps 4 & 5 for each KeyFob to be enrolled
Press [RESET] on Keypad
10
STEP 3
- ENROLLING USER CODES
Enroll Mode LED will flash / pulse
The keypad will give error beeps -
ignore.
System will Arm
System will Disarm
System will automatically test
code by quickly Arming and
Disarming.
Exit Enroll Mode - the Enroll
Mode LED will go out