NAPCO 2WAY-UNIVKF Installation Instructions Manual
NAPCO 2WAY-UNIVKF Installation Instructions Manual

NAPCO 2WAY-UNIVKF Installation Instructions Manual

Bi-directional lcd keyfob
Hide thumbs Also See for 2WAY-UNIVKF:

Advertisement

2WAY-UNIVKF
®
Bi-Directional LCD KeyFob
Installation Instructions
WI1024B 03/01
© NAPCO 2001

Advertisement

Table of Contents
loading

Summary of Contents for NAPCO 2WAY-UNIVKF

  • Page 1 2WAY-UNIVKF ® Bi-Directional LCD KeyFob Installation Instructions WI1024B 03/01 © NAPCO 2001...
  • Page 2 2WAY-UNIVKF - The 2-Way Universal LCD Keyfob that puts the power of a keypad in your pocket. NAPCO introduces the new 2WAY-UNIVKF, the security industry’s only Easy LCD ICON Indicators universal bi-directional Keyfob with LCD status display and integral mini Burglar Alarm sounder, supported by a revolutionary 2-way receiver.
  • Page 3: Table Of Contents

    UNIVERSAL MODE - TYPICAL APPLICATIONS....18 overview on page 4. WARRANTY................20 NAPCO Security Systems, Inc. For Technical Assistance, Contact the NAPCO 333 Bayview Avenue l Amityville, New York 11701 (800) 645-9440 Toll Free Helpline For Sales and Repairs, call Toll Free: (800) 645-9445...
  • Page 4: System Overview

    SYSTEM OVERVIEW The 2WAY-UNIVKF is compatible with virtually any control panel either through bus compatible operation or universal mode operation. When used on a panel on which it is bus-compatible, full functionality is realized, including lighting, appliance and X10 control. When used in the Universal Mode, functionality is dependent on the feature set of the control panel, such as a keyswitch arm zone for arm / disarm capability, an armed output to provide an Armed indication, a steady bell output for an alarm indication and a pulsing bell output for a fire alarm indication.
  • Page 5: Wiring Diagram/ Configuration

    WIRING DIAGRAM AND SYSTEM CONFIGURATION Enroll Mode Push Button Receiver LED System Configuration Jumpers 1 2 3 4 5 6 7 8 9 10 • • 9 10 11 13 14 15 Receiver LED Indications KeyFob Enroll Mode Rapid Flash User Enroll Mode Rapid Flash / Pulse Universal Mode...
  • Page 6: Controls And Audible Indicators

    ∗ ∗ System Trouble icon(s) will † Press ON/OFF and simultaneously to second garage automatically go out activate lighting or other special application.† door. † in about 6 seconds. 6... Alarm ! (repeats) † Bus Operation Only WI1024B 2WAY-UNIVKF Installation Instructions...
  • Page 7: Visual Indicators

    Visual LCD Indicators The 2WAY-UNIVKF uses a series of icons to convey the status of the system. Each time the STATUS button is pressed, or a command is issued, the appropriate icon(s) will display for about 6 seconds. For example, if ON/OFF is pressed to arm the system, the Armed Icon will light in a few seconds to confirm that the command was successfully carried out.
  • Page 8: Bus Mode Wiring And Config

    Wiring GREEN The 2WAY-UNIVKF is compatible with the keypad bus of the NAPCO Gemini YELLOW GEM-P816, GEM-P1632, GEM-P3200 and GEM-P9600 control panels. It is also compatible with the keypad bus of the Ademco models Vista 10 and 20.
  • Page 9: Bus Mode Enrolling Keyfobs

    Exit Enroll Mode - the Enroll Mode LED will go out • All instructions which require keystroke entry on the NAPCO or Ademco keypad will be followed by the appropriate button in [NAPCO] / [Ademco] format. For example [ON/OFF] / [STAY].
  • Page 10: Bus Mode Enrolling User Codes

    System will automatically test code by quickly Arming and Disarming. Repeat steps 4 & 5 for each KeyFob to be enrolled • Press [RESET] on Keypad Exit Enroll Mode - the Enroll Mode LED will go out WI1024B 2WAY-UNIVKF Installation Instructions...
  • Page 11: Bus Mode Garage Door & Special Apps

    GARAGE DOOR CONTROL / SPECIAL APPLICATIONS When installed on the bus of a Gemini Series or Ademco control panel, the receiver Relays 1 and 2 are available for other applications such as lighting or appliance control, while Relay 3 remains dedicated to the control of a garage door opener. It is also possible to configure Relay 2 to control a second garage door (or other access application requiring a momentary closure).
  • Page 12: Bus Mode - Typical Applications

    10 11 12 13 14 15 16 10 11 12 13 14 15 16 Door 2 Appliance Appliance GEMINI SYSTEM ARMED SYSTEM ARMED SYSTEM ARMED 01/01/00 12:00 AM Appliance 01/01/97 12:00AM 01/01/97 12:00AM GEM-X10 NEXT/YES PRIOR/NO AREA COMPUTERIZED SECURITY SYSTEM WI1024B 2WAY-UNIVKF Installation Instructions...
  • Page 13: Universal Mode Wiring Arm/Disarm/Panic

    24 hour panic zone, which will process a 2 second violation as a panic alarm. The wiring instructions below series. include wiring schemes for control panels which support zone doubling, such as the NAPCO Express Wiring for Panic Wiring for Arm / Disarm Program a zone on the control panel for “Keyswitch Arm”...
  • Page 14: Universal Mode Enrolling Keyfobs

    To remove a lost KeyFob from the system: Enter and then exit the Keyfob Enroll Mode. (Hold down Enroll Mode Push Button until Enroll Mode LED flashes, release and then hold down again to exit Enroll Mode). All keyfobs will be deleted from system. WI1024B 2WAY-UNIVKF Installation Instructions...
  • Page 15: Universal Mode Arm / Alarm Sense

    STEP 3 - WIRING FOR ARM & ALARM SENSE Wiring for Alarm Sense Wiring for Arm Sense In Universal Mode, the receiver requires an Alarm output from In Universal Mode, the receiver requires an Armed output from the control panel in order to pass the correct status to the the control panel in order to pass the system status to the KeyFob.
  • Page 16: Universal Mode Wiring For Stay Mode

    Program the control panel for “Automatic Interior Bypass”, or for “Home Away with Delay” (for the NAPCO Express Series stay mode). Each time the system is armed by a press of KeyFob button [ON/OFF], the system will arm in the AWAY mode, providing complete protection.
  • Page 17: Universal Mode Garage Door Control

    GARAGE DOOR CONTROL Wiring for Garage Door Control Changing the KeyFob battery In Universal operation, the 2WAY-UNIVKF may be used to Open battery compartment on back of Keyfob. control a garage door opener, or any other access control device which requires a momentary closure for activation.
  • Page 18: Universal Mode - Typical Applications

    (2) Enable Armed Output on PGM [25-4]. (4) For BOTH Fire AND Burg sense, (2) IN4001 (3) Program Zone 5 for 24 Hour [05-5]. Garage Door Garage Door (4) Enable Home/Away with Delay [01-X] for all Control Control WI1024B 2WAY-UNIVKF Installation Instructions...
  • Page 19 TYPICAL APPLICATIONS Typical Universal Mode applications with EOLR Control Panels using Arm and Alarm sense with Stay Mode and Garage Door control. DSC Power 832 BELL + 24 BELL - 23 PC5010 COM 18 AUX PWR + 17 Z8 16 KEYSWITCH ARM ZONE (1) COM 15 15 16 17 18 19 20 21 22 23 24...
  • Page 20: Warranty

    EXPRESS OR IMPLIED, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S NAPCO is not an insurer of either the property or safety of the user's family or employees, OWN NEGLIGENCE OR FAULT.

This manual is also suitable for:

Keyfob

Table of Contents