Compartment Installation - Keston C45 Installation And Servicing Instructions

Fan powered high efficiency modulating domestic condensing gas boiler
Table of Contents

Advertisement

WD536
A Below or beside openable window, air brick,
etc.
B Below gutters, soil pipes, drain pipes.
C Below eaves (unventilated)
D Below balconies or car port roof.
E From vertical drain or soil pipes.
F From internal or external corner or
boundary lines
G Above ground or balcony or roof.
H From surface or boundary line facing a
terminal
I
From terminal facing a terminal.
J From opening in a car port.
K Vertically from terminal on same wall.
L Horizontally from terminal on same wall.
Table 2.8.5
2.8.6
Clearances From Wall
Flue outlet and air inlet terminations must be at least 40 mm from the wall face.
2.8.7
Distance Between Flue Outlet & Air Inlet
There is no maximum - the terminations must not be on opposite sides of the
dwelling but can be in areas of unequal pressure
A minimum clearance of at least 300mm must be left between the terminations
and the flue terminal must be directed away from the air intake terminal.
2.8.8
General Installations
All parts of the system must be constructed in accordance with BS 5440 Part 1,
except where specifically mentioned in these instructions.
All pipe work must be adequately supported.
All joints other than push-on or plastic compression connectors must be made
and sealed with solvent cement suitable for muPVC pipes and conforming to BS
6209: 1982.
Consideration must be given to Corgi/Gas Safe bulletin TB200/TB008 regarding
flues in voids.
The boiler casing must always be correctly fitted to the boiler when leaving the
appliance operational.
External wall faces and any internal faces of cavity walls must be made good. For
50mm muPVC terminals, rubber collars are available for flue and air terminals to
finish the external wall face around the terminals (Part No C.08.0.00.07.0)
2.9
AIR SUPPLY
The C45, C40P and C55(P) are room sealed appliances and therefore do not require
purpose provided ventilation to the boiler room for combustion air.
2.10

COMPARTMENT INSTALLATION

The C45, C40P and C55(P) models operate with very low heat emission levels. As a
results the boilers can be installed in a compartment without ventilation.
Installation & Servicing Instructions
Chapter 2 - Boiler Location
Dimensions (mm)
Minimum Flue Terminations & Air Inlet Dimensions
The Keston C45, C40P, C55 & C55P
Flue
Air
Terminal
Inlet
300
75
200
200
75
200
200
600
1,200
1,200
1,200
1,500
1,500
300
50
75
50
50
50
50
100
100
100
300
Page : 17