Keston C45 Installation And Servicing Instructions page 16

Fan powered high efficiency modulating domestic condensing gas boiler
Table of Contents

Advertisement

WD536
Expansion
Pipe
C45
or
C55
FLOW
RETURN
Rad. 2
valves are closed, then the safety valve may be omitted. Note that the minimum
static head required is 9 ft at the top of the boiler.
Although suitable for open vented systems with combined feed and vent
arrangements, the C45, C40P and C55(P) are low water content boilers. As such,
any air entrainment within the system water will produce boiler "kettling". It is
therefore recommended, if in any doubt, to consider the use of sealed systems
where possible.
2.7.2
Sealed Systems
Sealed systems must be designed in accordance with BS 5449 and BS 7074 Pt1.
A typical sealed system is shown in Figure 2.7.2. It must include :
(i)
(ii)
(iii)
(iv)
(v)
(vi)
Installation & Servicing Instructions
Chapter 2 - Boiler Location
28mm
Safety
Minimum
Valve
(See note 2.7.1)
By-pass
A safety valve fitted on the flow, adjacent to the boiler. It must be non
adjustable and preset to 3 bar. A drain pipe must be attached, at least as
big as the valve connection, and routed to drain in any area
hazardous nor where it may be subject to freezing.
An expansion vessel complying with BS 4814 and sized in accordance
with the requirements of BS 5449 and BS 7074 Pt 1. The vessel must
be positioned on the primary return to the boiler. Table 2.7.2
Expansion Vessel Selection provides guidance for the correct expansion
vessel size to use.
A filling point, in accordance with local water authority requirements.
A method of system make-up (automatic or manual), in accordance with
local water authority requirements.
There must be no permanent connection of mains water to the boiler
system.
The installation must be designed to work with flow temperatures of up to
o
110
C.
The Keston C45, C40P, C55 & C55P
Figure2.7.1 : Open Vented System Diagram
Expansion
Tank
Minimum
9ft Height
Rad. 1
Cylinder
Valve
L/S
Valve
Valve
not
Page : 11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C40pC55C55p

Table of Contents