Model Number Identification - Rheem Seven Instructions Manual

Classic rpne-series

Advertisement

All controls and compressor are accessible
for servicing by removal of the service panel.
Drawn Painted Base Pan.

Model Number Identification

R
P
N
RHEEM
REMOTE
HIGH
HEAT PUMP
EFFICIENCY
(STANDARD)
2
Rheem Heating, Cooling and Water Heating
E
018
DESIGN
COOLING
SERIES
CAPACITY
018 = 18,000 BTU/HR [5.28 kW]
024 = 24,000 BTU/HR [7.03 kW]
030 = 30,000 BTU/HR [8.79 kW]
036 = 36,000 BTU/HR [10.55 kW]
042 = 42,000 BTU/HR [12.31 kW]
048 = 48,000 BTU/HR [14.07 kW]
060 = 60,000 BTU/HR [17.58 kW]
Engineering Features
RPNE- Series Heat Pump Outdoor Unit
1. Scroll compressor is hermetically sealed and incorporates internal
high temperature motor overload protection, and durable insulation on
the motor windings. It is externally mounted on rubber grommets to
reduce vibration and noise.
2. Copper Tube/Aluminum Fin Coils—Both indoor and outdoor coils.
3. Strong, Attractive Cabinet—Constructed of powder painted steel.
Louvered design protects the coil from damage.
4. Internal Check Valve—Provides for more quiet refrigerant metering.
5. Enhanced Compressor Protection—Features an enhanced defrost
control, auto-reset high pressure control, and auto-reset low
pressure control to provide compressor protection under abnormally
high head pressure conditions (outdoor fan failure, restriction, dirty
coil, etc.) or abnormally low suction pressure conditions (restrictions,
TXV failure, loss of charge, indoor blower failure, etc.) while
eliminating nuisance tripping sometimes experienced with
conventional control systems.
6. Drawn Painted Base Pan—For extra corrosion resistance and sound
reduction.
7. Demand Defrost Control—Provides complete defrost when defrost is
required.
8. Non-Cycling Reversing Valve—Eliminates discharge noises on each
heating cycle.
9. Hot Gas Muffler—Reduces noise in heating cycle.
10. Bi-Directional Filter Drier—Standard on all models.
11. Service valves are standard on all models.
12. Refrigerant Metering—TX valves accurately meter refrigerant into
indoor and outdoor coils.
13. The RPNE has a 10 year limited compressor warranty.
14. All refrigerant connections are on the exterior of the unit, located close
to the ground for neat appearing installations.
15. Coil design permits compressor operation with the access panel
removed.
16. Control box is fully accessible in the upper part of the cabinet, just
under the access panel.
17. Power and control wiring are kept separate.
18. Every unit is factory charged and tested.
J
ELECTRICAL
DESIGNATION
A-SERIES = FULL-FEATURED
J = 208/230V-1-60
C = 208/230V-3-60
D = 460V-3-60
Y = 575V-3-60
(4&5 TON ONLY)
A
Z
VARIATIONS
COOLING
CONNECTION
FITTING
Z = SWEAT W/SCROLL
[ ] Designates Metric Conversions